background image

ACM-IP2.1 

ANALOGUE SUBSYSTEMS MODULE

 

 

 User Manual 

armtel.com

 

 

стр.

 9/32 

[email protected] 

 

© Armtel

 

ENG 

1.5 Design 

1.5.1 ACM-IP2.1 represents a printed board with installed electrical components. The 

board is installed into the housing (see Figure 2) intended to secure a standard DIN-rail 

35 mm.  

ACM-IP2.1 weight does not exceed 0,2 kg. External appearance and overall dimensions 

are given at Figure 2. 

 

 line connector (connection of 1-8 control lines); 2 

 transparent flap cover; 3 

 housing;  

 nameplate; 5 

 offset lines 5…8 on/off switch (counter call on 5-8 control lines);  

 offset lines 1…4 on/off switch (counter call on 1-4 control lines); 7 

 CP on/off switch (

А

-

В

 

line output transformer central point control); 8 

 CPU0 operation readiness LED indicator; 

 CPU1 LED (mot used); 10 

 DEF button (reset to factory settings); 11 

 RES button (reset);  

12 

 Eth connector to connect to Ethernet network with PoE support; 13 

 A B CP +V connector 

to connect to analog control line and transformer central point control line;  

14 

 –IN –OUT 0 V 0 V connector to connect to external 48VDC power supply;  

15 

 attachment latch. 

Figure 2 

 ACM-IP2.1 external appearance and overall dimensions 

 

 

Summary of Contents for ACM-IP2.1

Page 1: ...ACM IP2 1 Analogue subsystems module RMLT 465275 015UM User Manual Document version 26 30 2 2021 ENG...

Page 2: ...armtel com Armtel info armtel com...

Page 3: ...with automation and alarm units Short name of the product is ACM IP2 1 ACM IP2 1 is used at the enterprises of metallurgical chemical mining gas and oil producing metal working and wood working indus...

Page 4: ...connecting the product to the power supply make sure the power and communication cables are properly insulated protect power and communication cables from damage To avoid electric shock do not operat...

Page 5: ...Operating limits 15 2 2 Safety precautions 15 2 3 Preparation for use 16 2 4 Installation connection and dismantling 17 2 4 1 Installation 17 2 4 2 Connection 18 2 4 3 Dismantling 19 2 5 Operation 20...

Page 6: ...h other digital communication system users directly handle priority connections and manage communication and indication modes An IP network based on standard network equipment is used to facilitate co...

Page 7: ...intercom analog intercom IP2 1 module Ethernet interface Fast Ethernet switch Ethernet interface loud speaker DW IP2 CCS DIS IP2 Organization of loud speaking Public address General alarm sessions on...

Page 8: ...current consumption at nominal power supply voltage IEEE 802 3af Class 0 max A 0 35 Power consumption max2 W 3 5 Communication interfaces 100BaseT Ethernet Communication protocols Armtel IP SIP SNMP...

Page 9: ...egory of IP2 1 according to GOST 15150 69 and values of exposure factors are given in Table 2 Table 2 Values of exposure factors Climatic category according to GOST 15150 69 Values of exposure factors...

Page 10: ...cs Note RMLT 465275 015 ACM IP2 1 Analogue subsystems module 1 Additional info on scope of supply Connector 15EDGK 3 81 04P 14 00A H 1 Mating connector A B CP V Connector 15EDGK 3 81 08P 14 00A H 1 Ma...

Page 11: ...3 housing 4 nameplate 5 offset lines 5 8 on off switch counter call on 5 8 control lines 6 offset lines 1 4 on off switch counter call on 1 4 control lines 7 CP on off switch line output transformer...

Page 12: ...central point control line 14 connector for connection of external DC power supply 48 W In case of no PoE it is used as an input for power supply connection When ACM IP2 1 is supplied from PoE it is u...

Page 13: ...be turned off Positions of CP switch a off position on default b I on for analog intercoms 8 CPU0 operation readiness indicator LED It flashes if the integrated software is loaded and operates correc...

Page 14: ...F OFF SD card not included in the scope of supply Process at the factory OFF ON eMMC Primary when supplied ON OFF NAND Not used ON ON NAND Not used X2 not used in this version of the device XP1 UART p...

Page 15: ...g information name trademark and reference information of the manufacturer product name and designation rated supply voltage permitted ambient temperature range commercialization mark for products on...

Page 16: ...name trademark and reference information of the manufacturer handling symbols to GOST 14192 96 and CU TR 005 2011 commercialization mark for products on the market of Customs Union member states seria...

Page 17: ...stated in Occupational Safety Rules When Operating Electrical Installations 2 1 2 ACM IP2 1 can be powered from PoE injector and 48 VDC external power supply 15 W min 2 1 3 The requirements for operat...

Page 18: ...ectors buttons switches all buttons switches shall be easy to press and must easily return to the original position check settings of Offset lines 5 8 Offset lines 1 4 and CP switches as per 1 5 1 con...

Page 19: ...cting the power and communication wires as well as for maintenance 2 4 1 Installation To attach ACM IP2 1 at the workplace the housing has a latch to secure to DIN rail 35 mm The unit is attached as p...

Page 20: ...ignment of the connector is given in Table 1 by a cable with maximum wire cross section of 28 to 16 AWG maximum cross section of crimped wire is 0 5 to 1 5 mm2 crimped by a connector from the scope of...

Page 21: ...der power off the device remove the device from the DIN rail as per Figure 4 1 use a screwdriver suitable in size to loosen the fixing spring on the attachment latch a 2 hold the housing cover and gen...

Page 22: ...M IP2 1 configuration key button functions can be programmed the volume of the integrated speaker external loudspeaker and microphone sensitivity can be set using the IPN system Administrator PC Note...

Page 23: ...lace the connection cable operability of connectors if necessary replace connectors on the connection cable if the Eth connector is faulty contact the manufacturer for repair power is supplied to PoE...

Page 24: ...ct the manufacturer for diagnostics and repair Device is not loaded S1 DIP switch is incorrectly set Set the DIP switch as per the installed memory type see 1 5 1 Loud speaking system does not transmi...

Page 25: ...stated in Occupational safety rules when operating electrical installation Also observe safety precautions given in 2 2 during maintenance 3 3 Maintenance procedure Maintenance includes the following...

Page 26: ...2019 Unified system for design documentation Guidelines for Preparation of Operating Documents for form filling 3 4 Checking operability The efficiency of ACM IP2 1 should be tested with equipment con...

Page 27: ...ported according to group Zh as per GOST 23216 78 and group 5 OZh4 as per GOST 15150 69 in consumer package as a packaging unit by road river railway and air transport except unsealed compartments wit...

Page 28: ...line LF transformer middle point 4 V Reception transmission external control 1 Line 1 Control line 1 discrete input output 2 Line 2 Control line 2 discrete input output 3 Line 3 Control line 3 discre...

Page 29: ...rmtel ENG Table A 1 The pin numbers and the designation of the circuits for external connection end Connector Contact No Identification Function 1 IN 48 V Power input when externally supplied 2 OUT 48...

Page 30: ...REFERENCE EXAMPLES OF ACM IP2 1 CONNECTION 1 An example of connection of analog intercom to ACM IP2 1 is shown in Figure B 1 Figure B 1 Connection of analog intercom Similar to the intercom keys the o...

Page 31: ...oud speaking alarm system with the help of ACM IP2 1 up to eight zones is illustrated at Figure B 2 Figure B 2 Construction of zonal loud speaking alarm system Note This diagram is an example for cons...

Page 32: ...32 armtel com Armtel info armtel com ENG 3 An example for construction an interaction scheme with automation and alarm devices dry contacts to ACM IP2 1 is shown in Figure B 3 Figure B 3 Interaction s...

Page 33: ...ACM IP2 1 ANALOGUE SUBSYSTEMS MODULE User Manual armtel com 31 32 info armtel com Armtel ENG NOTES...

Page 34: ...ACM IP2 1 ANALOGUE SUBSYSTEMS MODULE User Manual 32 32 armtel com Armtel info armtel com ENG...

Page 35: ...armtel com info armtel com Armtel...

Page 36: ...and physical address Russia 192012 Saint Petersburg Zaporozhskaya str 12 building 1 office 1 2 TECHNICAL SUPPORT 8 800 500 90 17 for calls from Russian Federation 7 812 633 04 02 for international ca...

Reviews: