background image

6

 12.   END-TO-END LINKING OF SMALL AND LARGE 

CANOPIES AND OFFSETTING SAME-SIZED CANOPIES

Hinge parts that will be positioned between the tension  
cables on large panels must be inserted into the extrusion 
channel before the large canopy is tensioned. Check  
the orientation of these hinge parts carefully as they are  
inserted into the channel to ensure that they will mate  
up properly when the small canopy is connected.

See the example below.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This method of assembly for linking hinges also applies to 
installations with staggered same-size panels. See the example 
with offsetting 4' x 10' panels below. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

WARNING: Do not attempt to remove the tension cable 

from a canopy that is suspended. Doing so may cause 

serious bodily injury.

Large

Extrusion

Small

Extrusions

Shown in boxed insets: Parts 
of two Single Hinge Linking Kits 
that must be inserted before 
tensioning panels. A total of six 
Single Hinge Linking Kits are 
used when connecting four small 
canopies and one large canopy 
as pictured in application.  
(See BPCS-3910 Infusions

®

 

Accent Canopies Data Page, 
page 9, for other hardware 
accessory kits used in this 
application.) 

Shown in boxed insets: Parts of 

two Single Hinge Linking Kits 

that must be inserted before 

tensioning panels. A total of four 

Single Hinge Linking Kits are 

used in this application to 

connect three large canopies.

Summary of Contents for INFUSIONS Accent Canopies Series

Page 1: ...after the tensioning cables have been installed Follow these guidelines for minimum distance from standard light sources Lamp Type Label Wattage Minimum Distance Halogen FL XL PAR 30 60 14 Incandescen...

Page 2: ...required for this operation with larger panels CAUTION Only use cables from Panel Kits for tensioning panels Cables from Kit 7004 7005 and 7010 shown in section 6 are only for hanging panels Hill and...

Page 3: ...Gripper Anchor Cap Bottom End Cable Adjuster Gripper Bottom End Assembly 4 Insert Top Cable into Bottom End Cable Adjuster and thread cable thru opening NOTE Gripper Structure Anchors have 1 4 20NC i...

Page 4: ...rmit attaching rows of end linked canopies side to side with either no space between them a 1 2 of space or a space of 3 11 1 Use the Dual Canopy Hanging Kit item 7041 at linked canopy ends A dual ass...

Page 5: ...e the same process for all hinge assemblies The end of the Hinge Rod will always be flush with an extrusion 11 5 Use this hardware the Dual Hinge Flush Linking Kit item 7045 to join paired canopies en...