10.  SIDE-TO-SIDE LINKED CANOPIES

To link canopies side-to-side, use one of three hardware  
kits: 7042 Flush Spacing Kit, 7043 1/2" Spacing Kit, or  
7007 3" Spacing Kit.

Example: 3" Spacing Kit 

– 7007 

Links two canopies side-to-side at one end  with 3" spacing.

Kit Contents: 
 

• (2) Locking Clips 

 

• (1) Linking Rod 

 

• (1) 3" Spacer

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

C

C

3" Linking Kit E

Linking Assembly Layout

Linking Rod and 

3" Spacer

Locking Clips

 

 
The spacing kits can also be used to link canopies  
side-by-side at the end of a continuous run of canopies  
linked end-to-end.

11.  END-TO-END LINKED CANOPIES (SAME SIZE)

These instructions depict hardware designed to allow two  
or more Infusions

®

 Canopies of the same size to be linked 

end-to-end. Additional components permit attaching rows of 
end-linked canopies side-to-side with either no space between 
them, a 1/2" of space, or a space of 3". 

 11.1

   Use the Dual Canopy Hanging 

Kit (item 7041) at linked canopy 
ends. A dual assembly will 
support one end of each of the 
linked canopies. The length of  
the yoke can be adjusted  
by means of a setscrew 
accessible from the bottom of 
the adjuster. Loosen the screw 
and slip the cable so that each 
leg evenly supports the weight 
of the attached canopies. 
Retighten the setscrew.

 11.2

   Smaller canopies that are joined end-to-end, but not 

side-to-side must have at least three points of support. 
One cable is connected to the center of one extrusion 
and two cables should be located in the second slot 
from each end of the extrusion at the opposite end. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

NOTE:

 Each 4' x 10' canopy must have four points of  

support. Two cables are to be located in the second slot from 
the end of each extrusion.

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for INFUSIONS Accent Canopies Series

Page 1: ...after the tensioning cables have been installed Follow these guidelines for minimum distance from standard light sources Lamp Type Label Wattage Minimum Distance Halogen FL XL PAR 30 60 14 Incandescen...

Page 2: ...required for this operation with larger panels CAUTION Only use cables from Panel Kits for tensioning panels Cables from Kit 7004 7005 and 7010 shown in section 6 are only for hanging panels Hill and...

Page 3: ...Gripper Anchor Cap Bottom End Cable Adjuster Gripper Bottom End Assembly 4 Insert Top Cable into Bottom End Cable Adjuster and thread cable thru opening NOTE Gripper Structure Anchors have 1 4 20NC i...

Page 4: ...rmit attaching rows of end linked canopies side to side with either no space between them a 1 2 of space or a space of 3 11 1 Use the Dual Canopy Hanging Kit item 7041 at linked canopy ends A dual ass...

Page 5: ...e the same process for all hinge assemblies The end of the Hinge Rod will always be flush with an extrusion 11 5 Use this hardware the Dual Hinge Flush Linking Kit item 7045 to join paired canopies en...

Page 6: ...th offsetting 4 x 10 panels below WARNING Do not attempt to remove the tension cable from a canopy that is suspended Doing so may cause serious bodily injury Large Extrusion Small Extrusions Shown in...

Page 7: ...will generate the greatest amount of pendulum reaction during a seismic event and should therefore be avoided When it is not practical to use cables greater than 20 long allow lateral clearance aroun...

Page 8: ...ation and many other technical services call TechLine customer support at 1 877 276 7876 or FAX 1 800 572 TECH For the latest product selection and specification data visit armstrongceilings com infus...

Reviews: