Thermostat
DIP Switch Settings and On-Board Links
Wiring Connections
DIP Switch 1
Thermostat
Heating
Stages
On Board Links Must Be Cut To Select
System Options
2 Heat / 2 Cool
OFF
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
2 Heat / 2 Cool
with t'stat with
humidity control
OFF
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
CUT ON-BOARD LINK
W914
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
2 Heat / 1 Cool
with t'stat with
humidity control
OFF
CUT ON-BOARD LINK
W914
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
*Not required on all units
2 Heat / 1 Cool
OFF
DO NOT CUT ANY
ON-BOARD LINKS
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
*
G
G
O
W1
W1
W2
C
C
C
Y1
Y1
Y1
R
R
R
Y2
DS
W2
*
G
G
O
W1
W1
W2
C
C
C
Y1
Y1
Y1
R
R
R
DS
W2
DS
*
G
G
O
W1
W1
W2
C
C
C
Y1
Y1
Y1
R
R
R
DS
W2
DS
Y2
Y2
Y2
*
G
G
O
W1
W1
W2
C
C
C
Y1
Y1
Y1
R
R
R
DS
W2
Y2
Y2
Y2
Field Wiring Applications with Conventional Thermostat (Continued)
Table 13B.