507581-04
Page 44 of 59
Issue 1933
Thermostat
DIP Switch Settings and On-Board Links
Wiring Connections
DIP Switch 1
Thermostat
Heating
Stages
On Board Links Must Be Cut To Select
System Options
1 Heat / 1 Cool
NOTE - Use DIP
switch 2 to set
second-stage
heat ON delay.
OFF-7 minutes.
ON-12 minutes.
ON
DO NOT CUT ANY
ON-BOARD LINKS
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
1 Heat / 2 Cool
NOTE - Use DIP
switch 2 to set
second-stage
heat ON delay.
OFF-7 minutes.
ON-12 minutes.
ON
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
1 Heat / 2 Cool
with t'stat with
humidity control
NOTE - Use DIP
switch 2 to set
second-stage
heat ON delay.
OFF-7 minutes.
ON-12 minutes.
ON
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
CUT ON-BOARD LINK
W914
DEHUM
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
*Not required on all units
*
G
G
O
W1
W1
W2
C
C
C
Y2
Y2
Y1
Y1
Y1
R
R
R
Y2
DS
DS
*
G
G
O
W1
W1
W2
C
C
C
Y2
Y2
Y1
Y1
Y1
R
R
R
Y2
DS
*
G
G
O
W1
W1
W2
C
C
C
Y1
Y1
Y1
R
R
R
Y2
DS
W2
Field Wiring Applications With Conventional Thermostat
Table 13A.