Inline
solenoid
valve
Inline service
valve with filter
Inlet elbow
15 to 10mm
compression
2x Couplers
G1/2” female
thread to
15mm
compression
Spout inlet
pipe Ø10mm
Short copper
pipe Ø15mm
Short copper
pipe Ø15mm
Copper supply
pipe Ø15mm
Filter
cap
Isolating
screw
FLOW
DIRN
FLOW
DIRN
7
5.2
Plumbing Overview
Once the spout has been secured to the panel,
consideration should be given to installing &
positioning of the inline valves.
A typical plumbing installation example is
shown here. The water is being supplied from
below, but can be from any direction.
Short lengths of Ø15mm copper pipe
(not supplied) have been used between the
components. Copper pipe lengths should be
cut to suit the suit the installation.
Note the Ø10mm inlet pipe (fitted to spout) can
be trimmed if necessary.
Observe arrow markings on the
valves as shown here. Ensure water
flows in the direction indicated.
4. To fit inlet elbow:
Slip the small compres-
sion nut & olive onto the Ø10mm inlet pipe.
Push the elbow onto the inlet pipe up to the
shoulder. Slide the olive up to the elbow &
tighten the compression nut (19mm A/F) with
a spanner. Hold the elbow steady with suit-
able grips.
ENSURE INLET PIPE REMAINS SECURELY
SCREWED INTO SPOUT.
INSTALLATION GUIDE continued…
4
5
19 & 24