INSTALLATION GUIDE
DO NOT
apply heat near this product. Heat generated by soldering
could damage plastic parts and seals.
5.1 Mounting
Before connection, flush water through pipe-work to
remove all debris etc. to prevent damage to the valve
mechanism.
THEN ENSURE WATER SUPPLIES HAVE BEEN
ISOLATED.
2.
Fit the larger rubber washer, brass washer & back-nut onto the spout tail as shown from behind the
panel.
3.
Hand tighten the nut against the brass washer until the rubber washer makes contact with the rear of
the panel. Ensure the spout is positioned correctly, & then tighten the back-nut securely with a 36mm
A/F spanner.
CABLE COLOURS:
The cables emerging from the spout are connected to the integral sensor.
BLACK & RED cables will connect to the solenoid valve.
GREY cable will connect onto the PCB inside the PSU
Do not cut these cables
.
DRILL PANEL
HOLE Ø35 MIN,
Ø40 MAX
1
3
2
36
INSTALLATION HEIGHT: we recommend the spout outlet be positioned approximately 150-200mm
above the basin or worktop (which ever is higher). Greater height may cause users to splash water out-
side the basin whereas lower height may affect activity space. Consideration should also be give to the
overall aesthetical appearance. Installations vary significantly, so use this dimension as a guideline only.
1.
Remove the spout mounting kit if al-
ready assembled to the spout tail. Screw
the copper inlet pipe into the spout, trim
to length if necessary. Ensure the rubber
washer (smaller diameter one) is in place
as shown. This seal should locate into the
recess of the escutcheon. Offer the spout
towards the hole in the panel.
Feed the inlet pipe, cables
& tail through panel hole.
Push the spout against the
panel & ensure the rubber
washer makes contact.