Arlec PA9000 Instruction Manual Download Page 7

7

TROUBLESHOOTING

Unit does not operate 

Is the unit plugged in? 

Is the power outlet switched on?

Is the Full Water indicator on?

(If so empty the condensed water)

Unit does not seem to cool effectively

Is the room too large?

Is there direct sunlight onto the unit?
(close curtains and pull down blinds)

Are windows or doors open?

Is there another heat source in the room?

Is the filter dusty or contaminated?

Is the air intake blocked?

Is the outlet duct venting the hot air 
properly?

Is the room temperature below your
selected temperature?

Too Noisy

Is the unit positioned on an uneven hard
floor surface creating vibration?

Note: A soft carpeted surface may absorb
excessive vibration

The Compressor does not operate

Has the overheating protective device
operated? If so allow time for the 
compressor temperature to decrease. 
The device will automatically reset

Important Note: This unit is built in
accordance with relevant safety and
performance standards. An electrical
specialist must carry out repairs.

SPECIFICATIONS 
Input power consumption : 

1000 watt (1.3 horsepower)

Cooling capacity : 

9000 BTU/hr (2600 watt)

Air volume moved at max. fan setting:

360 cubic metres/hr

CPIN_518-2  15/9/04  5:08 PM  Page 7

Summary of Contents for PA9000

Page 1: ...ditioner Instruction Manual PA9000 IMPORTANT Please read these instructions carefully before use Due to continuous research and development the specifications herein are subject to change without notice CPIN_518 2 15 9 04 5 08 PM Page 1 ...

Page 2: ...y with this appliance This appliance is not intended for use by children or infirm persons without supervision DO NOT conduct repairs on this unit It has been built in accordance with relevant safety and performance standards An electrical specialist must carry out all repairs DO NOT use the unit without the filter fitted ALWAYS unplug the unit from the mains before maintenance or cleaning ALWAYS ...

Page 3: ...ng hole for connection to air outlet duct 4 Round connector 5 Round connector cap 6 Drain tray 7 Drain hose AIR CONDITIONER 8 Drain cap 9 Caster 10 Control panel 11 Cooling air outlet 12 Handle 13 Air filter 14 Air inlet 15 Exhaust air outlet 16 Cord storage hook 2 1 10 12 9 11 13 14 15 16 8 3 3 4 5 6 7 CPIN_518 2 15 9 04 5 08 PM Page 3 ...

Page 4: ...ossible length Prevent any bow or bend in the middle of the duct as this will trap hot exhaust air which will radiate into the room and cause the unit to shut off automatically due to overheating IMPORTANT The duct length has been specifically designed for this product Do not replace or lengthen the duct with attachments If the venting of the exhaust air is inhibited in any way the unit may over h...

Page 5: ...sition NOTE The cooling system compres sor will switch off when the ambient temperature becomes lower than the preset temperature The fan however will continue to operate normally Regulating air flow direction To control the air flow direction via the vertical louvers rotate the central lever at the bottom of the grille To control the air flow direction via the horizontal louvers adjust louvers ma...

Page 6: ... wipe the body clean Never use aggressive chemicals petrol detergents chemically treated cloths or harsh cleaning solutions these may cause permanent damage to the external surface Cleaning the filter Use a vacuum cleaner or just tap the filter lightly to remove loose dust and dirt Rinse with hot water no hotter than 40 o C then dry thoroughly before replacing Important Note Never operate the unit...

Page 7: ...ture below your selected temperature Too Noisy Is the unit positioned on an uneven hard floor surface creating vibration Note A soft carpeted surface may absorb excessive vibration The Compressor does not operate Has the overheating protective device operated If so allow time for the compressor temperature to decrease The device will automatically reset Important Note This unit is built in accorda...

Page 8: ...the purchaser wish to make a claim under the guarantee the product should be returned pre paid to the place of purchase To obtain warranty the purchase receipt must be returned with the product This guarantee is in addition to and does not take away from any rights available to the consumer under the Trade Practices Act and the State consumer protection legislation 24 month guarantee applies for d...

Reviews: