Temporary Location

The air outlet duct maybe fitted directly
into the circular opening of the foam strip
supplied to provide a temporary type
installation in a window opening. The
foam strips can be cut or trimmed to fit
the desired shape.

Permanent Location

The round connector (item 4) may be fit-
ted into a circular opening cut into a wall
or glass window. This connector, when
not in use, can be left in position with the
opening covered by the cap provided.

ASSEMBLY

Fitting the air outlet duct

This air conditioner is required to have
the air outlet duct fitted to an external
opening to exhaust the hot air. 

The duct can be extended from 39cm to
150cm long, however it is recommended
to use the shortest possible length.
Prevent any bow or bend in the middle of
the duct, as this will trap hot exhaust air,
which will radiate into the room and
cause the unit to shut off automatically
(due to overheating).

IMPORTANT! The duct length has
been specifically designed for this
product. Do not replace or lengthen
the duct with attachments.

If the venting of the exhaust air is
inhibited in any way the unit may
over heat and shut off.

The location may be either a temporary or
permanent type depending on your
requirements. If you wish to frequently
move the unit from room to room without
creating a permanent opening in a wall or
window, you can use the foam strips as
described below under temporary location. 

If you wish to have an place set aside
where you can connect and operate the
unit on a continuous basis you can use
the round connector, as described below
under permanent location

CPIN_518-2  15/9/04  5:08 PM  Page 4

Summary of Contents for PA9000

Page 1: ...ditioner Instruction Manual PA9000 IMPORTANT Please read these instructions carefully before use Due to continuous research and development the specifications herein are subject to change without notice CPIN_518 2 15 9 04 5 08 PM Page 1 ...

Page 2: ...y with this appliance This appliance is not intended for use by children or infirm persons without supervision DO NOT conduct repairs on this unit It has been built in accordance with relevant safety and performance standards An electrical specialist must carry out all repairs DO NOT use the unit without the filter fitted ALWAYS unplug the unit from the mains before maintenance or cleaning ALWAYS ...

Page 3: ...ng hole for connection to air outlet duct 4 Round connector 5 Round connector cap 6 Drain tray 7 Drain hose AIR CONDITIONER 8 Drain cap 9 Caster 10 Control panel 11 Cooling air outlet 12 Handle 13 Air filter 14 Air inlet 15 Exhaust air outlet 16 Cord storage hook 2 1 10 12 9 11 13 14 15 16 8 3 3 4 5 6 7 CPIN_518 2 15 9 04 5 08 PM Page 3 ...

Page 4: ...ossible length Prevent any bow or bend in the middle of the duct as this will trap hot exhaust air which will radiate into the room and cause the unit to shut off automatically due to overheating IMPORTANT The duct length has been specifically designed for this product Do not replace or lengthen the duct with attachments If the venting of the exhaust air is inhibited in any way the unit may over h...

Page 5: ...sition NOTE The cooling system compres sor will switch off when the ambient temperature becomes lower than the preset temperature The fan however will continue to operate normally Regulating air flow direction To control the air flow direction via the vertical louvers rotate the central lever at the bottom of the grille To control the air flow direction via the horizontal louvers adjust louvers ma...

Page 6: ... wipe the body clean Never use aggressive chemicals petrol detergents chemically treated cloths or harsh cleaning solutions these may cause permanent damage to the external surface Cleaning the filter Use a vacuum cleaner or just tap the filter lightly to remove loose dust and dirt Rinse with hot water no hotter than 40 o C then dry thoroughly before replacing Important Note Never operate the unit...

Page 7: ...ture below your selected temperature Too Noisy Is the unit positioned on an uneven hard floor surface creating vibration Note A soft carpeted surface may absorb excessive vibration The Compressor does not operate Has the overheating protective device operated If so allow time for the compressor temperature to decrease The device will automatically reset Important Note This unit is built in accorda...

Page 8: ...the purchaser wish to make a claim under the guarantee the product should be returned pre paid to the place of purchase To obtain warranty the purchase receipt must be returned with the product This guarantee is in addition to and does not take away from any rights available to the consumer under the Trade Practices Act and the State consumer protection legislation 24 month guarantee applies for d...

Reviews: