10

11

TROUBLE SHOOTING

GBIN004060

GBIN004060

PROBLEM

CAUSE

SOLUTION

The unit does not come ON.

Unit not plugged in.

Make sure the plug is pushed in 
completely and power switch is 
switched ON.

Internal safety device has operated.

Wait for 30mins and try again.

Wall socket is not working.

Check with another working  
wall socket.

The overflow indicator displays “FL”.

Empty the water inside the tank.

Unit works for a short  
time only.

Bends or kinks in the air exhaust hose.

Position the hose properly, keeping it 
as short as possible with no bends.

Air outlet/inlet grilles are blocked.

Visual inspect the unit to make sure 
no foreign material is obstruction the 
airflow.

Unit does not cool the room.

Room size too large.

Unit is suitable for a room size of 
16m

2

 with a standard ceiling height 

of 2.4m.

Direct sunlight onto the unit.

Close curtains and pull down blinds.

Windows or doors open.

Close doors and windows.

Another heat source in the room.

Eliminate all other heat sources. 

Outlet duct venting the hot air properly.

Adjust the hose properly so that 
there is no back flow of hot air in  
the room.

Room temperature below your 
selected temperature.

Adjust the room temperature.

Unit is too noisy.

Unit placed on a hard surface  
causing it to vibrate.

A soft carpeted surface may absorb 
excessive vibration.

The unit does not operate  
for about three minutes after 
it is restarted.

This is for the safety of the compressor 
which prevents the unit from being 
restarted until three minutes have 
elapsed since it was last turned off.

This is part of normal operation.

1. 

Screw off the drain cap and drain the water in the water tray to another vessel that holds water. 

Note: The tilt angle of the unit shall not be greater than 30 degrees. 

2. 

Start the unit, turn the mode to the low fan speed state of the air supply mode, keep this state for half a 

day and dry the interior of the unit to prevent mold. 

3. 

Turn off the unit, unplug the power plug, wrap the power cord around the wire-winding post, install the 

water plug and drain cap. 

4. 

Remove the exhaust hose assembly and keep it in a secure place. 

5. 

Pack the air-conditioner properly with soft plastic bag, put the unit in a dry place & take appropriate 

dust-proof measures, and keep the unit out of the reach of children. 

6. 

Take out the batteries of the remote control and keep them in a secure place. 

Note: Ensure that the unit is put in a dry place. All accessories of the unit should be stored  

in a secure place.

END OF SEASON STORAGE

MAINTENANCE

Clean the surface of the unit with wet soft cloth. Do not use chemical solvents such as alcohol and gasoline; 

otherwise, the surface of the air conditioner may be damaged and even the whole unit may be damaged.

If the filter screen is clogged with dust, and the effectiveness 

of the air conditioning is reduced, be sure to clean the filter 

screen once every two weeks.
Clean the upper filter screen frame:
1. Unscrew the screw provide in the middle of the EVA filter. 

Clasp the wedging block of the EVA filter screen frame 

with hands. Force down from the outside to remove the 

EVA filter screen frame as shown. 

PLEASE NOTE: When taking out the filter frame, the 

force shall be applied evenly on the wedging block.  

Be sure to take out the filter frame first and then take 

out the filter mesh.

2. Use vacuum cleaner to remove the dust from the filter 

frame. If the frame is very dusty place it in the warm water 

under 40°C or 104°F to which neutral detergent is added 

for cleaning and then dry them in the shade. Rinse the 

filter and dry it in a shaped place. 

NOTE: Do not damage the mesh fabric on the filter 

frame and filter mesh.

Prior to maintenance and servicing of the unit, turn off the power and unplug the plug.

SURFACE CLEANING

CLEAN THE FILTER SCREEN

Remove 

Screw

EVA 

Filter

Summary of Contents for PA0802GB

Page 1: ...ntinuous research and development the specifications herein are subject to change without notice Important Please read these instructions carefully GBIN004060 PORTABLE AIR CONDITIONER Instruction Manual PA0802GB ...

Page 2: ...or turn the breaker OFF ALWAYS unplug the unit from the mains before maintenance or cleaning ALWAYS keep a clearance of at least 200mm from walls furniture and curtains ELECTRICAL CONNECTIONS Before you plug the appliance into the mains socket check the following The appliance shall be installed in accordance with national wiring regulations Power rating of the mains wall socket is adequate for th...

Page 3: ...around the Unit when the hose is not connected Mounting in the Wall Correct Bending 1 Place the hose inlet over the exhaust outlet by sliding in the Hose Inlet 2 This air conditioner is required to have the exhaust hose fitted over the hose inlet Pull few threads of the exhaust hose Fix the exhaust hose to the moulded threads on hose Inlet by turning it in a counter clockwise direction The exhaust...

Page 4: ...ng green light next to the timer icon will glow Also the timer count will be display on the display screen Set the time between 1Hrs to 24Hrs after which you want the unit to be turned ON using the UP DOWN button on the remote or control panel Once the time is selected the corresponding time will blink for 5 times on the display and the count is stored in the memory The unit will start operating o...

Page 5: ...SAFETY FEATURES FROST PROTECTION FUNCTION LOW TEMPERATURE The unit is fitted with a frost protection device to avoid excessive formation of ice during Cooling Dry or Sleep mode The unit will start automatically when defrosting process is completed OVERFLOW PROTECTION FUNCTION When water in the water pan exceeds the warning level the machine will automatically sound an alarm and the FULL indicator ...

Page 6: ...state of the air supply mode keep this state for half a day and dry the interior of the unit to prevent mold 3 Turn off the unit unplug the power plug wrap the power cord around the wire winding post install the water plug and drain cap 4 Remove the exhaust hose assembly and keep it in a secure place 5 Pack the air conditioner properly with soft plastic bag put the unit in a dry place take appropr...

Page 7: ...nuing as if the repaired or replacement product was supplied at the original date of purchase Your statutory rights remain unaffected and nothing in this warranty shall limit or exclude our liability for any rights you have under the Consumer Rights Act 2015 If any part of this warranty is deemed unenforceable including any exclusion of liability the enforceability of any other parts of this warra...

Reviews: