Arlec PA0802GB Instruction Manual Download Page 2

2

3

SAFETY INSTRUCTIONS

IDENTIFICATION

Please read carefully and keep the manual in a safe 
place for future reference

Before using the machine:

•  This appliance is not intended for use by persons 

(including children) with reduced physical, 
sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been 
given supervision or instruction concerning use 
of the appliance by a person responsible for their 
safety.

•  Children should be supervised to ensure that they 

do not play with the appliance.

•  DO NOT operate the unit with a damaged plug or 

loose wall outlet. If the supply cord is damaged, it 
must be replaced by the manufacture, its service 
agent or similarly qualified person in order to 
avoid a hazard.

•  DO NOT connect the unit unless it completely 

assembled.

•  DO NOT rest heavy objects on to the unit

•  DO NOT tilt the unit. Always keep the unit in 

upright position and on a flat/ stable surface, 
where it cannot be easily fall over.

•  DO NOT pull or carry the appliance by the power 

cord. This may cause a portion of the core wire to 
break, which may cause overheating or fire.

•  DO NOT run the power cord under carpeting  

and rugs

•  DO NOT cover or obstruct the air inlet or  

outlet grilles

•  DO NOT use the device in the following cases

-   Near a fire source 
-    In areas where gasoline, paint or other 

flammable goods are stored

-   In an area where the water can be projected 
-   In a wet room, such as a bathroom or laundry

•  Before cleaning the unit, switch it OFF and 

disconnect the power plug or turn the breaker 
OFF. This may cause injury, since the fan inside 
rotates at high speeds during operation.

•  DO NOT touch the plug or device by wet hands or 

bare feet 

•  DO NOT insert or allow foreign objects to enter the 

grille openings as this may cause damage to the 
unit and/or user.

•  DO NOT turn the breaker OFF/ON or disconnect/

connect the power plug during operation. This 
may create sparks, which can cause fire.

•  This appliance has been manufactured for 

domestic environments for indoor use only and 
should not be used for other purpose

•  DO NOT use an extension cord with this unit

•  The supplier is not liable for injury caused 

to person or property damage due to non-
compliance with maintenance instruction, 
improper use of the appliance or not use genuine 
part from official supplier. If service is needed 
contact an authorized service agent

•  When the unit will be unused for a long time, 

disconnect the power plug or turn the breaker OFF

•  ALWAYS unplug the unit from the mains before 

maintenance or cleaning

•  ALWAYS keep a clearance of at least 200mm from 

walls furniture and curtains

ELECTRICAL CONNECTIONS

Before you plug the appliance into the mains socket, check 
the following:

•  The appliance shall be installed in accordance  

with national wiring regulations.

•  Power rating of the mains wall socket is adequate for 

the appliance, check the value indicated on the product 
rating label placed on back of the unit.

•  Mains wall socket is properly earthed.

PLEASE NOTE: Failure to follow these important safety 
instructions absolves the manufacturer of all liability.

ENERGY SAVING TIPS 

•  Use the unit in the recommended room size of up to 

16m2 (assuming standard 2.4m ceiling height)

•  Do not locate the air conditioner where furniture or other 

objects can obstruct the air flow.

•  Keep blinds/curtains closed during the sunniest part of 

the day.

•  Close the fireplace damper, floor and/ or wall registers, 

so cool air does not escape through the chimney or duct 
work.

•  Keep the air filter clean. Under normal conditions, the 

filters should be cleaned approximately every 30 days. 
Since the filters remove airborne particles, more frequent 
cleaning maybe necessary, depending on the indoor air 
quality.

•  Set the unit to maximum cooling and high speed 

ventilation for the initial startup, then adjust the unit down 
to a more comfortable setting as required.

Top 

Cover
Control 

Panel

Condensation 

Filter

Drainage 

Hole

Carry 

Handle

Air Outlet/

Louver

Front 

Housing

Exhaust 

Outlet

EVAP 

Filter

Casters

Front View

Rear View

GBIN004060

GBIN004060

Important information for correct disposal of the product 
in accordance with EC Directive 2002/96/EC.

At the end of its working life, the product must not be 
disposed of as urban waste. It must be taken to a special 
local authority differentiated waste collection centre or to 
a dealer providing this service. Disposing of a 
household appliance separately avoids possible 
negative consequences for the environment 
and health deriving from inappropriate disposal 
and enables the constituent materials to be 
recovered to obtain significant savings in energy 

and resources. As a reminder of the need to dispose of 
household appliances separately, the product is marked with 
a crossed-out wheeled dustbin.

DISPOSAL OF THE UNIT

As required by Regulations, prior to disposing of this air 
conditioner the refrigerant gas contained in this unit MUST 
be removed and disposed of via a licensed refrigeration 
mechanic. Please contact your local air conditioning service 
centre to arrange for proper gas removal and disposal.

Summary of Contents for PA0802GB

Page 1: ...ntinuous research and development the specifications herein are subject to change without notice Important Please read these instructions carefully GBIN004060 PORTABLE AIR CONDITIONER Instruction Manual PA0802GB ...

Page 2: ...or turn the breaker OFF ALWAYS unplug the unit from the mains before maintenance or cleaning ALWAYS keep a clearance of at least 200mm from walls furniture and curtains ELECTRICAL CONNECTIONS Before you plug the appliance into the mains socket check the following The appliance shall be installed in accordance with national wiring regulations Power rating of the mains wall socket is adequate for th...

Page 3: ...around the Unit when the hose is not connected Mounting in the Wall Correct Bending 1 Place the hose inlet over the exhaust outlet by sliding in the Hose Inlet 2 This air conditioner is required to have the exhaust hose fitted over the hose inlet Pull few threads of the exhaust hose Fix the exhaust hose to the moulded threads on hose Inlet by turning it in a counter clockwise direction The exhaust...

Page 4: ...ng green light next to the timer icon will glow Also the timer count will be display on the display screen Set the time between 1Hrs to 24Hrs after which you want the unit to be turned ON using the UP DOWN button on the remote or control panel Once the time is selected the corresponding time will blink for 5 times on the display and the count is stored in the memory The unit will start operating o...

Page 5: ...SAFETY FEATURES FROST PROTECTION FUNCTION LOW TEMPERATURE The unit is fitted with a frost protection device to avoid excessive formation of ice during Cooling Dry or Sleep mode The unit will start automatically when defrosting process is completed OVERFLOW PROTECTION FUNCTION When water in the water pan exceeds the warning level the machine will automatically sound an alarm and the FULL indicator ...

Page 6: ...state of the air supply mode keep this state for half a day and dry the interior of the unit to prevent mold 3 Turn off the unit unplug the power plug wrap the power cord around the wire winding post install the water plug and drain cap 4 Remove the exhaust hose assembly and keep it in a secure place 5 Pack the air conditioner properly with soft plastic bag put the unit in a dry place take appropr...

Page 7: ...nuing as if the repaired or replacement product was supplied at the original date of purchase Your statutory rights remain unaffected and nothing in this warranty shall limit or exclude our liability for any rights you have under the Consumer Rights Act 2015 If any part of this warranty is deemed unenforceable including any exclusion of liability the enforceability of any other parts of this warra...

Reviews: