8
9
WATER DRAINAGE
1. Once the unit shuts down upon full water, turn
off the power of the unit and then unplug the
power plug.
Note: Move the unit carefully to avoid spillage
of water in the water tray at the bottom of
the unit.
2. Put a vessel/container that will hold the water
below the water outlet at the back of the unit.
3. Unscrew the drainage cap and plug in the water
pipe on the drain plug. Put the container to store
the drained water; the water will automatically
flow into the water container.
PLEASE NOTE: The drainage pipe and
container is not provided with the unit.
Only applicable to cooling and
dehumidifying mode:
1. Unscrew the drainage cover, and unplug
the water plug.
2. Set the drainage pipe into the water outlet.
3. Connect the drainage pipe to the bucket.
NOTES:
1. Keep the drainage cap and the water plug securely for later use.
2. During drainage, the unit can be tilted slightly backwards to undergo the drainage
process smoothly.
3. If the water container cannot hold all the water, before the water container is full, insert the water
outlet with the water plug as soon as possible to prevent any spill of water on the carpet or floor area.
4. When the water is discharged, insert the water plug, and tighten the drainage cover.
Notes: Restart the machine after the water plug and drainage cover are installed,
otherwise condensate water of the machine will flow to the floor or the carpet.
MANUAL DRAIN
CONTINUOUS DRAINAGE (OPTIONAL)
Drainage
Cap
Drainage
Pipe (not
included)
GBIN004060
GBIN004060
PLUG WIRING
SAFETY FEATURES
FROST PROTECTION FUNCTION (LOW TEMPERATURE)
The unit is fitted with a frost protection device to avoid excessive formation of ice during Cooling, Dry
or Sleep mode. The unit will start automatically when defrosting process is completed.
OVERFLOW PROTECTION FUNCTION
When water in the water pan exceeds the warning level, the machine will automatically sound an alarm,
and the “FULL” indicator light will flash. At this point, you need to move the drainage pipe connecting the
machine or the water outlet to a suitable drainage area to empty the water (For details, refer to the Drainage
Instructions section in the instructions). After the water is emptied, the machine will automatically return to
the original state.
PROTECTION FUNCTION OF THE COMPRESSOR
To increase the service life of the compressor, it has a 3-minute delay booting protection function
after the compressor is turned off.
Plug must also be fitted with a genuine BS1362 approved fuse with the
below rating which is dependent on the rated wattage of the product.
Fuse Rating
Rated Power
3A
Up to 700W
5A
Up to 1150W
13A
Up to 3000W
NOTE: The plug is incorporated with a 13Amp fuse.
F
U
S
E
BROWN
15
mm O ALL
6
mm BARE
BLUE
25
mm O ALL
6
mm BARE
45
mm O ALL
6
mm BARE
GREEN &
YELLOW
N
L
INSIDE
VIEW
O CORD.GRIP O
These safety instructions should be read
carefully and kept in safe place for future
reference.
The appliance is fitted with a plug
that complies with BS1363.
Wires colour code as below:
Brown
– Live
Blue
– Neutral
Yellow & Green – Earth
If the appliance is fitted with a 2-core cable
it is double insulated and will not have the
Earth (Yellow & Green) wire.
IT IS ESSENTIAL THAT THE WIRES ARE
ATTACHED ONLY TO THEIR DESIGNATED