Arlec PA0802GB Instruction Manual Download Page 5

8

9

WATER DRAINAGE

1.  Once the unit shuts down upon full water, turn 

off the power of the unit and then unplug the 

power plug. 

Note: Move the unit carefully to avoid spillage 

of water in the water tray at the bottom of  

the unit.

2.  Put a vessel/container that will hold the water 

below the water outlet at the back of the unit.

3.  Unscrew the drainage cap and plug in the water 

pipe on the drain plug. Put the container to store 

the drained water; the water will automatically 

flow into the water container.

PLEASE NOTE: The drainage pipe and  

container is not provided with the unit.
Only applicable to cooling and  

dehumidifying mode:
1.  Unscrew the drainage cover, and unplug 

the water plug.

2.  Set the drainage pipe into the water outlet.
3.  Connect the drainage pipe to the bucket.

NOTES:
1.  Keep the drainage cap and the water plug securely for later use. 
2.  During drainage, the unit can be tilted slightly backwards to undergo the drainage  

process smoothly.

3.  If the water container cannot hold all the water, before the water container is full, insert the water 

outlet with the water plug as soon as possible to prevent any spill of water on the carpet or floor area.

4.  When the water is discharged, insert the water plug, and tighten the drainage cover.
Notes: Restart the machine after the water plug and drainage cover are installed,  

otherwise condensate water of the machine will flow to the floor or the carpet.

MANUAL DRAIN

CONTINUOUS DRAINAGE (OPTIONAL)

Drainage 

Cap

Drainage 

Pipe (not 

included)

GBIN004060

GBIN004060

PLUG WIRING

SAFETY FEATURES

FROST PROTECTION FUNCTION (LOW TEMPERATURE)

The unit is fitted with a frost protection device to avoid excessive formation of ice during Cooling, Dry  

or Sleep mode. The unit will start automatically when defrosting process is completed.

OVERFLOW PROTECTION FUNCTION

When water in the water pan exceeds the warning level, the machine will automatically sound an alarm, 

and the “FULL” indicator light will flash. At this point, you need to move the drainage pipe connecting the 

machine or the water outlet to a suitable drainage area to empty the water (For details, refer to the Drainage 

Instructions section in the instructions). After the water is emptied, the machine will automatically return to 

the original state.

PROTECTION FUNCTION OF THE COMPRESSOR

To increase the service life of the compressor, it has a 3-minute delay booting protection function  

after the compressor is turned off.

Plug must also be fitted with a genuine BS1362 approved fuse with the  

below rating which is dependent on the rated wattage of the product.

Fuse Rating

Rated Power

3A

Up to 700W

5A

Up to 1150W

13A

Up to 3000W

NOTE: The plug is incorporated with a 13Amp fuse.

F

U

S

E

BROWN

15

mm O ALL

6

mm BARE

BLUE

25

mm O ALL

6

mm BARE

45

mm O ALL

6

mm BARE

GREEN &

YELLOW

N

L

INSIDE

VIEW

O CORD.GRIP O

These safety instructions should be read 

carefully and kept in safe place for future 

reference.
The appliance is fitted with a plug  

that complies with BS1363. 

Wires colour code as below:
Brown  

– Live 

Blue  

– Neutral 

Yellow & Green   – Earth 
If the appliance is fitted with a 2-core cable  

it is double insulated and will not have the 

Earth (Yellow & Green) wire.

IT IS ESSENTIAL THAT THE WIRES ARE 

ATTACHED ONLY TO THEIR DESIGNATED 

POSITION IN THE PLUG AS SHOWN .

Summary of Contents for PA0802GB

Page 1: ...ntinuous research and development the specifications herein are subject to change without notice Important Please read these instructions carefully GBIN004060 PORTABLE AIR CONDITIONER Instruction Manual PA0802GB ...

Page 2: ...or turn the breaker OFF ALWAYS unplug the unit from the mains before maintenance or cleaning ALWAYS keep a clearance of at least 200mm from walls furniture and curtains ELECTRICAL CONNECTIONS Before you plug the appliance into the mains socket check the following The appliance shall be installed in accordance with national wiring regulations Power rating of the mains wall socket is adequate for th...

Page 3: ...around the Unit when the hose is not connected Mounting in the Wall Correct Bending 1 Place the hose inlet over the exhaust outlet by sliding in the Hose Inlet 2 This air conditioner is required to have the exhaust hose fitted over the hose inlet Pull few threads of the exhaust hose Fix the exhaust hose to the moulded threads on hose Inlet by turning it in a counter clockwise direction The exhaust...

Page 4: ...ng green light next to the timer icon will glow Also the timer count will be display on the display screen Set the time between 1Hrs to 24Hrs after which you want the unit to be turned ON using the UP DOWN button on the remote or control panel Once the time is selected the corresponding time will blink for 5 times on the display and the count is stored in the memory The unit will start operating o...

Page 5: ...SAFETY FEATURES FROST PROTECTION FUNCTION LOW TEMPERATURE The unit is fitted with a frost protection device to avoid excessive formation of ice during Cooling Dry or Sleep mode The unit will start automatically when defrosting process is completed OVERFLOW PROTECTION FUNCTION When water in the water pan exceeds the warning level the machine will automatically sound an alarm and the FULL indicator ...

Page 6: ...state of the air supply mode keep this state for half a day and dry the interior of the unit to prevent mold 3 Turn off the unit unplug the power plug wrap the power cord around the wire winding post install the water plug and drain cap 4 Remove the exhaust hose assembly and keep it in a secure place 5 Pack the air conditioner properly with soft plastic bag put the unit in a dry place take appropr...

Page 7: ...nuing as if the repaired or replacement product was supplied at the original date of purchase Your statutory rights remain unaffected and nothing in this warranty shall limit or exclude our liability for any rights you have under the Consumer Rights Act 2015 If any part of this warranty is deemed unenforceable including any exclusion of liability the enforceability of any other parts of this warra...