2880R-LT, 2881R-LT, 2882R-LT
Revision 1.0
P a g e 5 | 28
Specification
Details
Installation Category
II
Pollution Degree
2
Equipment mobility
Fixed
Mechanical Specification:
Refer to Dimensional Drawing
Protection Degree –
Controller & Probe Junction
Box
IP65
2800 Series Controller And
Remote Level Probe
Certification
(Hazardous Locations)
North America
•
CSA file number: 56812
•
Class – 2258-02 – Process control equipment for Hazardous
Locations
•
Class – 2258-82 – Process control equipment for Hazardous
Locations – Certified to US Standards
•
Ex db IIC T5 Gb
•
Class I, Zone 1, AEx db IIC T5 Gb
International IECEx/ATEX
•
II 2G Ex db IIC T5 Gb
•
Sira 17ATEX1303X
•
IECEx CSA 17.0034X
SPECIFIC CONDITIONS OF USE FOR HAZARDOUS LOCATION
(denoted by X after the certificate number)
1. Process temperature for the standard and heavy duty probes are -60°C to +200°C and for
flexible probe is -60°C to +100°C. It is end-user’s responsibility to ensure that the ambient
around the Capacitance Controller and ARJAY Probe does not exceed the permitted ambient of
+55°C.
2. The maximum process pressure is 1500psi/ 10342KPa.
3. Only approved certified entry devices shall be used.
4. Flameproof joints are not permitted to be repaired in the field. If the flamepath is damaged, the
enclosure is to be removed from service and replaced with a new enclosure.