![Ariterm EKERUM Installation And Operating Instructions Manual Download Page 19](http://html1.mh-extra.com/html/ariterm/ekerum/ekerum_installation-and-operating-instructions-manual_2972144019.webp)
PELLET STOVE KMP EKERUM / NEPTUNI
ARITERM SWEDEN AB
Installation Instructions -
2011.08.19
- 19
/24
4.5 Hot air fan
Work is best carried out with both side hatches removed, but they can also be accessed
from one side or the other.
1. Remove the plug from the wall socket.
2. Open the filler hatch and slacken off the panel screws on the upper edge of the side hatch.
3. Pull the upper section of the hatch straight out and then lift up the panel so that it is free.
4. Disconnect the cables from the fan by pulling the plastic covered flat pin sleeves from
the motor.
5. Remove the screws that hold the fan brackets to the stove body (2 x).
6. Reinstall in reverse order.
4.6 Control circuit board
1. Remove the plug from the wall socket.
2. Remove one of the side hatches according to the Hot air fan section.
3.
Remove the edge connectors on the long sides of the control circuit board by pulling
them straight out from the circuit board.
4. Disconnect the cable for the control panel located in a connector on one edge of the
control circuit board. Press in the hook on the underside of the connector and pull the
cable straight out to the side.
5. Release the three panel screws on the rear of the stove and remove the control circuit
board.
4.7 Fuses
1. There are two fuses on the stove’s input connector. Both are 3.15A slow.
2. When replacing the fuses pull the connector cover straight out to access the
fuses (Fig. 11).
4.8 Overheat protection and safety switches
This work must be carried out by an authorised engineer.
Fig. 11