Icons displayed on the LCD 

Icons displayed on the LCD are shown below.

 

Table 5: LCD icons and descriptions  
Icon 

 

Description 

 

Day mode (network) 

This icon indicates that the primary sensitivity mode 

setting for control panels in the fire network is day 

mode. 

 

Day mode (control panel) 

This icon indicates that the sensitivity mode for the 

local control panel is day mode. Other control panels in 

the fire network may have a different sensitivity mode 

setting. 

 

Night mode (network) 

This icon indicates that the primary sensitivity mode 

setting for control panels in the fire network is night 

mode. 

 

Night mode (control panel) 

This icon indicates that the sensitivity mode for the 

local control panel is night mode. Other control panels 

in the fire network may have a different sensitivity 

mode setting. 

 

Fire alarms 

The number beside this icon indicates the number of 

zones with an active fire alarm. Alarm information for 

the first and last zones to report an alarm is displayed 

in the LCD message area

.

 

 

Faults 

The number beside this icon indicates the number of 

active faults. Additional information is available by 

pressing F1 (Show Events). 

 

Conditions 

The number beside this icon indicates the number of 

active system conditions (events). Additional 

information is available by pressing F1 (Show Events). 

 

Stand-alone 

This icon indicates that the control panel is not 

connected to the fire network. 

 

Networked 

This icon indicates that the control panel is connected 

to the fire network. 

 

Repeater 

This icon indicates that the control panel is configured 

to operate as a repeater and is connected to the fire 

network. 

 

Detector alarm [1] 

This icon indicates a detector alarm. 

 

Manual call point alarm [1] 

This icon indicates a manual call point alarm. 

 

Manual call point alarm 

(sprinkler) [1] 

This icon indicates a manual call point alarm 

(sprinkler). 

 

Manual call point alarm 

(“hausalarm”) [1] 

This icon indicates a manual call point alarm 

(“hausalarm”). This is a local alarm with no fire routing 

activation. 

[1] These icons appear in the message display area with the notification details. 

 

Summary of Contents for 2X Series

Page 1: ...2X Series Operation Manual P N 00 3250 505 0003 04 ISS 04MAY15 ...

Page 2: ... other relevant provisions of Directive 2004 108 EC 2012 19 EU WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info 2006 66 EC b...

Page 3: ...t overview 3 The user interface 3 Front panel controls and indicators 5 LCD controls and indicators 9 Acoustic indicators 11 Conditions 11 Status indications 12 Control panel operation 16 User levels 16 Operation controls and procedures 17 Public level operation 18 Operator level operation 21 Maintenance 26 Menu maps 27 Regulatory information 28 ...

Page 4: ...hether any remedy fails of its essential purpose Installation in accordance with this manual applicable codes and the instructions of the authority having jurisdiction is mandatory While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents UTCFS assumes no responsibility for errors or omissions Advisory messages Advisory messages alert you to...

Page 5: ...m repeater panel 2X F1 S One loop addressable fire alarm control panel 2X F1 FB2 S One loop addressable fire alarm control panel with fire routing and fire protection controls 2X F1 SCFB S One loop addressable SS 3654 fire alarm control panel with fire routing and fire protection controls 2 2X F2 S Two loop addressable fire alarm control panel 2X F2 PRT Two loop addressable fire alarm control pane...

Page 6: ... have a network board installed For more information on this feature contact your installation or maintenance contractor Fire routing and fire protection control and indication In this document information on control and indication for fire routing and fire protection applies only to control panels that include those features ...

Page 7: ...er Fault Disabled Test LED 9 Programmable output group start stop button and LED 10 Jog dial and function buttons 11 Reset button and LED 12 Panel Silence button and LED 13 Sounder Start Stop Button and LED 14 System Fault LED 15 Low Battery LED 16 Earth Fault LED 17 Supply Fault LED 18 Fire Protection Fault Disabled Test LED 19 Fire Protection Delay button and LED 20 Fire Protection On Acknowledg...

Page 8: ... Reset button and LED 14 Panel Silence button and LED 15 Sounder Start Stop Button and LED 16 System Fault LED 17 Low Battery LED 18 Earth Fault LED 19 Supply Fault LED 20 Fire Protection Fault Disabled Test LED 21 Fire Protection Delay button and LED 22 Fire Protection On Acknowledged button and LED 23 Fire Routing Fault Disabled Test LED 24 Fire Routing Delay button and LED 25 Fire Routing On Ac...

Page 9: ... repeater and evacuation panels Table 3 Common controls and indicators Control LED LED colour Description Supply LED Green Indicates that the system is powered up General Test LED Yellow Indicates that one or more features or devices are being tested General Disable LED Yellow Indicates that one or more features or devices are disabled General Fault LED Yellow Indicates a general fault The fault L...

Page 10: ...flashing LED indicates that fire protection has been activated A steady LED indicates that the fire protection signal has been acknowledged by the remote monitoring equipment Fire Protection Delay button and LED Yellow Enables or disables a previously configured fire protection delay Cancels a delay as it counts down and activates fire protection A steady LED indicates that a delay is configured a...

Page 11: ...ssing the button activates the sounders if the control panel status and operating mode allow manual activation of sounders The LED also indicates the status of the sounders Steady indicates that sounders are active or will be activated shortly Flashing indicates that a delay is counting sounders are activated when the configured delay elapses or when the delay is cancelled Off indicates that the s...

Page 12: ...s Red Yellow Starts or stops the the output group associated with the programmable button when pressed with the Confirm button A steady red LED indicates that the output group associated with the button is active A flashing red LED indicates that a delay is counting the output group is activated when the configured delay elapses or when the delay is cancelled A flashing yellow LED indicates a faul...

Page 13: ...t your installation or maintenance contractor LCD controls and indicators Figure 3 LCD controls and indicators 1 Day night mode indicator 2 System date and time and active fire routing delay or extended fire routing delay countdown 3 Control panel network status stand alone networked repeater 4 Current alarm fault and condition events counter 5 Message display area 6 Soft keys menu options linked ...

Page 14: ... and last zones to report an alarm is displayed in the LCD message area Faults The number beside this icon indicates the number of active faults Additional information is available by pressing F1 Show Events Conditions The number beside this icon indicates the number of active system conditions events Additional information is available by pressing F1 Show Events Stand alone This icon indicates th...

Page 15: ...ng tone is 50 ON and 50 OFF A short tone is 25 ON and 75 OFF Conditions A summary of system events logged as conditions is shown below Table 7 System events logged as conditions Condition type Description Alert A device is in alarm but the system is waiting for an additional alarm event to confirm the zone alarm Configuration device connected A control panel configuration session is initiated via ...

Page 16: ...he control panel status indications Standby Standby is indicated as follows The Supply LED is steady If a sounder delay has been enabled the Sounder Delay LED is steady If a fire routing delay has been enabled the Fire Routing Delay LED is steady If a fire protection delay has been enabled the Fire Protection Delay LED is steady Note Depending on your fire system configuration the buzzer may sound...

Page 17: ...able 3 on page 5 for more information If a fire routing delay has been enabled the Fire Routing Delay LED is steady The Fire Routing Delay LED flashes while the delay is counting When fire routing is activated the Fire Routing ON Acknowledged LED flashes If configured to do so by your installation or maintenance contractor a steady Fire Routing ON Acknowledged LED indicates that the fire routing s...

Page 18: ...d Supply Fault LED Additional information about the fault is displayed on the LCD Earth faults are indicated by a flashing General Fault LED and a flashing Earth Fault LED System faults are indicated by a flashing General Fault LED and a steady System Fault LED Low battery faults are indicated by a flashing General Fault LED and a steady Low Battery LED Additional information about the fault is di...

Page 19: ...nued operation Low battery is indicated as follows The General Fault LED is flashing The Low battery LED is steady An initial warning message indicating the low battery status is displayed on the LCD If the power issue is not fixed the batteries will continue to discharge until a second warning message is displayed indicating that the control panel will shut down The buzzer sounds intermittently l...

Page 20: ... levels Restricted user levels are protected by password security You are required to enter the username and password assigned to you by your maintenance or installation contractor The control panel automatically exits from a restricted user level and reverts to the public user level after two minutes if no button is pressed To enter a restricted user level 1 Press F4 Main menu The username and pa...

Page 21: ... waiting for input Configuration options The options listed below are available when making configuration changes to the control panel for example changing the password The control panel configuration and configuration revision is only updated when configuration changes are applied by pressing F3 Apply The configuration revision change and timestamp are recorded in the Revision report and can be a...

Page 22: ... enabled and active counting down press the Sounder Delay button to cancel the delay and activate sounders immediately A sounder delay is indicated as follows A steady Sounder Delay LED indicates that a delay is enabled A flashing Sounder Delay LED during a fire alarm indicates that the configured delay is active sounders are activated when the configured delay elapses or when the delay is cancell...

Page 23: ...pses or when the delay is cancelled Note A fire alarm activated by a manual call point overrides any configured delay and activates fire routing or fire protection immediately if configured Manually starting evacuation sounders See Manually starting evacuation sounders on page 22 Note Evacuation panels only Availability of this feature at this user level is subject to previous configuration by you...

Page 24: ...20 Note This information is only available if your installation or maintenance contractor has included it in the fire system configuration ...

Page 25: ...e alarm counter The Main menu The operator Main menu is shown below Figure 5 The operator Main menu Resetting the control panel To reset the control panel and clear all current system events press the Reset button System events that have not been resolved will continue to be reported after reset Caution Investigate all fire alarms and faults before resetting the control panel Manually starting sou...

Page 26: ...he time between the end of the configured disable time and the end of the configured sounder delay when the Sounder Start Stop LED is flashing pressing the Sounder Start Stop button silences sounders before activation A configured sounder delay may still be cancelled while the delay is running and sounders activated by pressing the Sounder Delay button Manually starting evacuation sounders To star...

Page 27: ...rol panel Attention required Displays all devices reporting a fault condition Revision Displays your control panel software revision control panel configuration revision and system boards serial number data Contact details Displays contact information for your installation or maintenance contractor subject to installer configuration Zone status 1 Displays the current status information for zones D...

Page 28: ...t to confirm that the LED indicators and control panel buzzer are working correctly To perform an LED and buzzer test 1 Select Tests from the Main menu 2 Select UI tests and then Indicators test During the test the control panel buzzer sounds and all LED indicators are steady The test continues for two minutes Press F2 Exit to exit the test before the default timeout Performing a keyboard test Per...

Page 29: ... an LCD test 1 Select Tests from the Main menu 2 Select UI tests and then LCD test A test pattern displays on the LCD to help identify the location of defective pixels 3 Press F2 Exit Viewing the alarm counter Select the Alarm counter option to view the total number of fire alarms recorded by the control panel The alarm counter value cannot be reset ...

Page 30: ...maintenance Contact your installation or maintenance contractor to carry out an annual inspection of the fire alarm system This inspection must test all system devices and verify that the control panel responds to all fault and alarm events All electrical connections must be visually inspected to make sure that they are securely fastened that they have not been damaged and that they are appropriat...

Page 31: ...tatus Device status Panel I O status Output groups status Rules status Firenet status Alarm counter Password setup Change password Table 12 Operator level menu for fire alarm repeater panels Menu level 1 Menu level 2 Menu level 3 Test UI test Indicator test Keyboard test LCD test Reports Event log View all Attention required Revision Firmware revision Configuration revision Serial numbers Contact ...

Page 32: ...e alarm routing equipment 2 7 10 Output to fire protection equipment type A B and C 3 7 11 Delays to outputs 4 7 12 Dependencies on more than one alarm signal types A B and C 4 7 13 Alarm counter 8 4 Total loss of the power supply 8 9 Output to fault warning routing equipment 9 5 Disablement of addressable points 4 10 Test condition 4 1 Excluding repeaters and control panels operating in EN 54 2 E...

Page 33: ... 2 1997 A1 2006 EN 54 4 1997 A1 2002 A2 2006 Product identification See model number on product identification label Intended use See DoP point 3 Essential characteristics See DoP point 9 EN 54 13 European compatibility assessment of system components These control panels form part of a certified system as described by the EN 54 13 Standard when installed and configured for EN 54 13 operation as d...

Page 34: ...30 ...

Page 35: ...31 ...

Page 36: ......

Reviews: