1X-F Series Operation 

Manual 

P/N 501-415003-2-50 • ISS 14JUN22 

Summary of Contents for 1X-F Series

Page 1: ...1X F Series Operation Manual P N 501 415003 2 50 ISS 14JUN22 ...

Page 2: ...sions of Directive 2014 30 EU 2012 19 EU WEEE Directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see recyclethis info 2006 66 EC Battery Directive This prod...

Page 3: ... 1 Sounder and fire routing delays 2 Control panel overview 3 User interface for two and four zone control panels 3 User interface for eight zone control panels 4 Operator controls and indicators 5 Audible indicators 9 Summary of status indications 9 Control panel operation 13 User levels 13 Public user level operation 14 Operator user level operation 17 Maintenance 25 Regulatory information 26 ...

Page 4: ...ardless of whether Carrier has been advised of the possibility of such damages and regardless of whether any remedy fails of its essential purpose Installation in accordance with this manual applicable codes and the instructions of the authority having jurisdiction is mandatory While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents Carrie...

Page 5: ...hat could result in injury or loss of life They tell you which actions to take or to avoid in order to prevent the injury or loss of life Caution Caution messages advise you of possible equipment damage They tell you which actions to take or to avoid in order to prevent the damage Note Note messages advise you of the possible loss of time or effort They describe how to avoid the loss Notes are als...

Page 6: ...iv 1X F Series Operation Manual ...

Page 7: ... not available for all operating modes For more information see Sounder and fire routing delays on page 2 Operating modes Supported operating modes are shown in the table below The default operating mode is EN 54 2 Table 2 Operating modes Operating mode Region EN 54 2 default European Union EN 54 2 Evacuation European Union Spain EN 54 2 Scandinavia European Union Scandinavia BS 5839 1 United King...

Page 8: ...r each operating mode Table 3 Sounder and fire routing delays Operating mode Sounder delay Fire routing delay Extended fire routing delay EN 54 2 Yes Yes Yes EN 54 2 Evacuation Yes No No EN 54 2 Scandinavia Yes Yes Yes BS 5839 1 Yes No No NBN S 21 100 Yes evacuation sounders Yes warning sounders No NEN 2535 No Yes Yes Note Fire routing is not available on any two zone control panel ...

Page 9: ...etworking Fault LED 8 Service Detector LED 2 9 Expansion I O Fault Disabled LED 10 General Disable button and LED 11 General Test button and LED 12 Configuration controls 13 Reset button and LED 14 Panel Silence button and LED 15 Sounder Start Stop button and LED 2 16 System Fault LED 17 Out of Service LED 18 Earth Fault LED 19 Supply Fault LED 20 Fire Routing Delay button and LED 1 2 21 Fire Rout...

Page 10: ...t LED 17 Out of Service LED 18 Earth Fault LED 19 Supply Fault LED 20 Fire Routing Delay button and LED 1 2 21 Fire Routing ON ACK and Fault Disable Test button and LEDs 1 2 Notes 1 Two zone control panels do not include fire routing or warning sounders for NEN 2535 2 Regional variants include changes to interface buttons and LEDs as shown in Table 4 below Table 4 Regional variants of interface bu...

Page 11: ...ual call point A yellow LED indicates a fault test or disablement in the corresponding zone A flashing yellow LED indicates a fault A steady yellow LED indicates that the zone is disabled or is being tested 2 Supply LED Green Indicates that the system is powered up correctly 3 General Fault LED Yellow Indicates a fault The corresponding zone device or function fault LED also flashes 4 General Fire...

Page 12: ...dicates the control panel is showing local information A continuous steady LED indicates the control panel connection to the network has been disabled A flashing LED indicates network faults 8 Service Detector LED Yellow Indicates a fault of detectors requiring service only for detectors supporting CleanMe functionality For zone information press and hold the Panel Silence button a flashing yellow...

Page 13: ...acknowledges all current events A steady LED indicates that all current events were acknowledged 15 Sounder Start Stop button and LED Red The LED indicates what happens when the button is pressed If the LED is on flashing or steady pressing the button silences the fire sounders If the LED is off pressing the button activates the sounders if the control panel status and operating mode allow manual ...

Page 14: ...r Warning Sounder Delay for NBN S 21 100 Yellow Enables or disables a previously configured fire routing or warning sounders delay For warning sounders this cancels a delay as it counts down and activates sounders A steady LED indicates that a fire routing or warning sounders delay is configured and enabled A flashing LED indicates that a fire routing or warning sounders delay is counting fire rou...

Page 15: ...teady if a fire routing or warning delay was enabled Control panel buzzer Off Fire alarm Fire alarm status is indicated as follows General Fire Alarm LEDs Flashing if the alarm was activated by a detector Steady if the alarm was activated by a manual call point Zone LED Flashing red if the alarm was activated by a detector Steady red if the alarm was activated by a manual call point Shows which zo...

Page 16: ...nd NBN S 21 100 operation In evacuation status the panel activates the sounders without detection of a zone alarm The status is indicated as shown below For EN 54 2 evacuation and NBN S 21 100 operation General Fire Alarm LEDs On steady Sounders Active sounding Sounder Start Stop LED On steady Control panel buzzer Sounding continuous For NBN S 21 100 operation additional indicators are Evacuation ...

Page 17: ...LED On steady Corresponding Zone LED On steady yellow Control panel buzzer Off Disabled sounders or evacuation for NBN S 21 100 are indicated as follows General Disable LED On steady Sounder LED On steady yellow Control panel buzzer Off Disabled fire routing or warning for NBN S 21 100 is indicated as follows General Disable LED On steady Fire Routing LED On steady yellow Control panel buzzer Off ...

Page 18: ...re Protection LED On steady yellow Control panel buzzer Off Out of service The control panel is out of service when there is insufficient or no mains or battery power Zone and input detection does not operate but the rest of the system is operational In this state the control panel may receive network events which activate its outputs Out of service is indicated as follows Out of Service LED On st...

Page 19: ...l The default password for the operator maintenance user is 2222 See Operator user level operation on page 17 for more information This is a restricted user level protected by password security To enter the operator user level enter the corresponding password using the numeric keypad and then press Enter A long beep and a steady Reset LED indicate that the correct password was entered and that the...

Page 20: ...events are acknowledged Cancelling an active sounder delay or evacuation delay for NBN S 21 100 If a sounder delay or evacuation delay for NBN S 21 100 is enabled and active press the Sounder Delay button or Evacuation Delay button for NBN S 21 100 to cancel the delay and activate sounders immediately Sounders for EN 54 2 evacuation and evacuation for NBN S 21 100 can cancel the delay and activate...

Page 21: ...elay is active Fire routing or warning for NBN S 21 100 is activated when the configured delay elapses or when the delay is cancelled A fire alarm activated by a manual call point overrides any configured delay and activates fire routing or warning for NBN S 21 100 immediately Performing a control panel LED indicator and control panel buzzer test To perform a control panel LED indicator and buzzer...

Page 22: ... and you need to identify which panel has a supply fault you should press Enter for 3 seconds The control panel without the supply fault will turn off the supply fault indication Example 2 If you have a 16 zone conventional system with two 8 zone conventional control panels which are not repeating each other then one panel has a zone range of 1 to 8 and the other panel has a zone range of 8 to 15 ...

Page 23: ...BN S 21 100 Enable or disable a configured fire routing delay or warning delay for NBN S 21 100 Enable or disable a configured extended fire routing delay Test a zone 1 Disable or enable a zone 1 Test sounders or evacuation for NBN S 21 100 Disable or enable sounders or evacuation for NBN S 21 100 1 Test fire routing or warning for NBN S 21 100 Disable or enable fire routing or warning for NBN S 2...

Page 24: ...ounders Start Stop LED is off and the sounders cannot be silenced before activation by pressing the Sounders Start Stop button During the time between the end of the configured disable time and the end of the configured sounder delay when the Sounders Start Stop LED is flashing pressing the Sounders Start Stop button silences sounders before activation A configured sounder delay may still be cance...

Page 25: ...ailability of this feature is subject to configuration and its functionality may vary for each zone Contact your fire system installation or maintenance contractor to confirm your configuration details Enabling or disabling a configured extended fire routing delay If configured the extended fire routing delay is enabled or disabled at the same time as the standard fire routing delay In NEN 2535 op...

Page 26: ...otherwise the control panel buzzer sounds continuously see note if no other zones are in alarm the control panel will reset automatically after 5 seconds and clear alarms for the zone in test If other zones are in alarm a manual reset is required To end the test press the Test button and then press the Zone button again If no action is taken the zone exits the test automatically after 1 hour If th...

Page 27: ...enable the zone press the General Disable button and then press the Zone button again If a disabled zone contains a device in alarm the zone will not be enabled until the control panel is reset Notes If it is the only zone in alarm no fire alarm or fault is indicated for the disabled zone and any linked fire outputs are stopped If one or more zones are in alarm when the zone is enabled the zone en...

Page 28: ...e Sounder Fault Disable Test button or Evacuation Fault Disable Test button for NBN S 21 100 again If there is a fire alarm the fire panel will exits the test and responds to the alarm as configured Disabling sounders or enabling sounders or evacuation for NBN S 21 100 To disable sounders or evacuation for NBN S 21 100 press the General Disable button and then press the Sounder Fault Disable Test ...

Page 29: ... Stop button for NBN S 21 100 again If there is a fire alarm the fire panel will exit the test and respond to the alarm as configured Disabling or enabling fire routing or warning for NBN S 21 100 To disable fire routing or warning for NBN S 21 100 press the General Disable button and then press the Fire Routing On Ack button or Warning Start Stop button for NBN S 21 100 Disabled fire routing or w...

Page 30: ...nds press the 1 and 3 buttons to select the option to be disabled the corresponding LED flashes and then press Enter to confirm the disablement Disablement is indicated as follows General Disable LED On steady Corresponding LED On steady yellow To enable a disabled option press the General Disable button for more than 3 seconds press the 1 and 3 buttons to select the option to be enabled and then ...

Page 31: ...fault and alarm events The control panel power supply and battery voltage should be checked Annual maintenance Contact your installation or maintenance contractor to carry out an annual inspection of the fire alarm system This inspection must test all system devices and verify that the control panel responds to all fault and alarm events All electrical connections must be visually inspected to mak...

Page 32: ...rotection equipment type A 2 7 11 Delays to outputs 7 13 Alarm counter 3 8 4 Total loss of the power supply 8 9 Output to fault warning routing equipment 2 10 Test condition 1 Excluding two zone models 2 NEN 2535 operating mode only 3 Dutch models only EN 54 13 European compatibility assessment of system components These control panels form part of a certified system as described by EN 54 13 when ...

Page 33: ...70 0832 Manufacturer Carrier Manufacturing Poland Spółka Z o o Ul Kolejowa 24 39 100 Ropczyce Poland Authorized EU manufacturing representative Carrier Fire Security B V Kelvinstraat 7 6003 DH Weert Netherlands Year of first CE marking 19 Year of first UKCA marking 22 Declaration of Performance number 1X F2 1X F2 SC 1X F4 1X F4 NL 1X F4 SC 1X F8 1X F8 NL 1X F8 SC 360 3100 0599 360 3100 0699 360 31...