1.   Installation must be carried out by a qualified personnel and in compliance  
to the local authority regulations. 
2.   This  heater  must  be  permanently  connected  to  the  direct  main  current  
supply. The use of a plug and socket is not recommended. 
3.  For the correct size of wire conductor corresponding to different electrical  
loading. Please refer to Table 1. 
4.  This  heater  operates  at  a  minimum  water  flow  rate  of  3.0  ltr/min  and  
maximum water pressure of 6 bar (Multi-Point). For direct connection to the  
water tank, the heater must have a minimum of 1.0m below the water tank. 
5. This heater will not function if there insufficient water flow (min. 3.0ltr/min)  
to trigger the flow switch. 
6. In time of thunder, turn off the electric current breaker in advance to protect 
the heater. 
7. The built-in ELCB will automatic cut off the power supply in case there is a 
current leakage as low as 15mA. 
8. The thermostat will automatic cut off the power supply if it has sensed an  
abnormal rise in showering water temperature.Only qualified technicians are 
allowed to reset the thermal cut-out built inside the appliances. 
9. (Model Multi-Point) Pressure Relief Valve is to prevents excessive built-up  
of water pressure to over 0.65 MPa (6.5bars). The excess will be discharged  
through the discharge nozzle, so it should not be removed from the heater. It  
is recommended to service the Pressure Relief Valve at least once a year to  
prevent blockage. 

Caution before  

installation ! 

1. Select a suitable position in the bathroom. 
2. Remove the screw A -(fig.2d) at the bottom of the unit and lift up the Front  
Cover first at the bottom and then unhook the two parts. Be careful not to  
break the Two hook which locate at the top of the Front cover . 
3. Mark the screws points of the Heater Base on the wall. The Heater position  
should be 1.5 meter from the bathroom floor. 
4. If Shower accessory is avaiable (refer fig.2b; 2c),  mark the screws points  
of  the  Slider  Rail  set  beside  the  Heater.  It is  recommended  the  top  of  the  
portion is in level with the top of the Heater. 
5.  Use  6mm  diameter  drill  and  make  the  wall  plug  holes  for  Heater  and  
Shower accessory to 34mm depth. 
6.  Insert  the  wall  plugs  and  mount  the  Heater  firmly  in  position  with  the   
screws provided. 
7. To mount Shower accessory, remove the Terminal cover from the Mounting  
terminal  and  screw  the  Mounting  to  position.  Close  the  cover.  Insert  the  
Shower Holder and Soap Tray into the Slider Rail. Mount the Slider Rail to the  
Mouting terminals and screw the second Mouting to position. Close the cover 

Install the  

appliance 

(For model Single-Point) 

1. Connect the Stop Valve to the Water Inlet with rubber washer. Use correct  
tools to tighten and be careful not to break the plastic nut. 
2. Insert Mesh Filter washer then connect the incoming water piping end to  
the Stop Valve (1/2" BSP). 
3. Connect the PVC Hose and Hand Shower to the outlet of the Heater, be  
sure to put in the rubber washer. 
4. Hook the Handshower to the Slider Rail Shower Holder and adjust to your  
ideal position. 

Important: The 'Water Outlet' can only be fitted to the PVC Hose and  
Handshower set provided. NO CONTROL VALVE OR FITTING CAN BE  
FITTED TO THE WATER OUTLET. 

(For model Multi-Point) 

1. Connect Pressure Relief Valve to INLET of water heater (if available). Use  
sealing  tape  for  the  connection  to  prevent  water  leakage.  DO  NOT  apply  
excessive force when tightening the Pressure Relief Valve. 
2. Insert Mesh Filter washer before connecting the incoming water supply to   
Pressure Relief Valve. 

Note : 
- When connect the Pressure Relief Valve to the water inlet, please make  
sure the discharge nozzle facing downward. Connect a discharge pipe (PVC  
tube  of  dia.  8.0mm)  to  the  discharge  nozzle  in  a  continuously  downward  
direction  and  this  pipe  must  be  left  open  to  the  atmosphere.  In  abnormal  
condition where pressure gets higher than 6.5 bar, water will drip from this  
discharge pipe. 
- Connections to the Multi-point hot water system should be limited to 2 or at  
the most 3 outlet usage points and they should be near to each other, e.g. in  
the same bathroom but only ONE OUTLET POINTS IS TO BE USED AT ANY  
ONE TIME. Extensive distance between the appliance and usage point(s) will  
result not only loss but also slow response of obtaining the hot water at the  
point(s) (fig.2a). 

Water  

connection 

* THE WATER INLET AND OUTLET MUST BE INSTALLED CORRECTLY,  
OTHERWISE THE HEATER CAN NOT FUNCTION. 
* DO NOT USE PLUMBING CEMENT ON CONNECTION. IF NECESSARY,  
USE ONLY THREAD OR SEALING TAPE.. 
Turn on the water mains to drain out all plumbing dirts and to fill up the heater  
tank  Check  for  any  water  leakage.  ( 

Important:This  step  will  prevent  

damage to the heating element 

). 

Testing  

connection 

Summary of Contents for WITH PUMP

Page 1: ...er 01 Ariston Thermo Group Viale Aristide Merloni 45 60044 Fabriano AN Italy T 39 0732 6011 F 39 0732 602331 www aristonthermo com GB Electric instant water heater VN Máy nước nóng trực tiếp M A X M A X ...

Page 2: ...l 3 ForSilent pump model 4 For model 2P2T only Single point Multi point indicator Serial number Model Rated Voltage Frequency Power Current Minimum flow rate allowable Maximum flow rate allowable IP protection grade and working pressure allowable For technical characteristics please refer to the appliance data plate Thank you for purchasing our instant water heater Please read the instruction care...

Page 3: ...th the screws provided 7 To mount Shower accessory remove the Terminal cover from the Mounting terminal and screw the Mounting to position Close the cover Insert the Shower Holder and Soap Tray into the Slider Rail Mount the Slider Rail to the Mouting terminals and screw the second Mouting to position Close the cover Install the appliance For model Single Point 1 Connect the Stop Valve to the Wate...

Page 4: ...upply from the mains is too cold or the flow too high In this case you can adjust the water inflow in order to get the desired showering temperature 5 Check the Built in ELCB as follow Press the TEST Button the unit should trip and cut off the power supply all LED lamps should light off Press the RESET Button the unit should resume back normal function Green LED lamp should light on If the above m...

Page 5: ...here are two filter located at the stop valve one is Mesh Filter installed at the incoming water supply another one is the built in Filter as shown in fig 8a Clean the Mesh Filter regularly to prevent blockage Remove the built in Filter by turn it anti clockwise as shown in fig 8a Take out the Filter and flush it with water to remove any trapped sediments as shown in fig 8b Clean the filter regula...

Page 6: ...6022E only Chỉ có ở kiểu BME6022 Screw A Vít A 185 5 292 2b PRESS BUTTON FOR HEIGHT ADJUSTMENT NHẤN NÚT ĐỂ ĐIỀU CHỈNH CHIỀU CAO FLEXIBLE ANGLE ADJUSTMENT ĐIỀU CHỈNH GÓC 5 SPRAY PATTERNS SELECTION LỰA CHỌN 5 CHẾ ĐỘ PHUN Slider Rail Bar Ống trượt Soap Tray Khay xà phòng Terminal cover Nắp che Screw Vít bắt Mounting terminal Đầu giữ ống Shower Holder Giá đỡ vòi sen Flexible Hose Ống mềm Hand Shower V...

Page 7: ...ontrol Knob Núm điều chỉnh nhiệt độ Front Cover Nắp mặt trước Position this way Quay về hướng này Position this way Quay về hướng này Position this way Quay về hướng này Pump Knob Núm điều chỉnh bơm 5 7 9a 9b 6 TEST LOW PRESSURE BOOSTER KHỞI ĐỘNG BƠM ÁP LỰC THẤP Release Button Nhấn nút để điều chỉnh độ cao Mist Column Ring Khoen gài Spray Ring Vòng phun Spray Ring Reatainer Vành giữ vòng phun MASS...

Page 8: ... 6 0 27 3 4 0 7 0 85 mm 56 0 30 mm 32 32 Pump Motor Thermostat Main Supply 220 240V a c E Earth N L Neutral Live Heating Element T2 T1 G ON OFF Switch Flow Switch M2Y N1 Heater Control Electronic ELCB 15mA Sensitivity G T1 Triac T2 ON OFF Switch Speed Control N L EP Model WIRING DIAGRAM MULTI POINT MODEL Auto Reset Thermostat Main Supply 220 240V a c E Earth N L Neutral Live Heating Element T2 T1 ...