70 /
MENU
SUB-
MENU
P
A
R
AME
TER
DESCRIPTION
RANGE
FACTORY SETTINGS
9
1
6
AFR contact confi guration (AUX Output 1)
None
Fault alarm
Humidistat alarm
External heat request
None
9
1
7
AUX Output 2
None
Fault alarm
Humidistat alarm
External heat request
None
9
1
8
AUX input 1 setting
None
Humidistat sensor
None
9
2
Energy Tariff Setting
9
2
0
Min Admit Electricity/Gas Cost Ratio
0,5 - 4
0,5
9
2
1
Max Admit Electricity/Gas Cost Ratio
0,5 - 4
4
9
2
2
kWh Primary Energy/kWh Elec Energy Factor
150 - 350
258
9
2
3
Gas kWh cost (GCV)
1 - 50 Euro, cent.
5 Euro, cent.
9
2
4
Electricity kWh cost
1 - 50 Euro, cent.
11 Euro, cent.
9
2
5
Electricity kWh cost (LOW TARIFF)
1 - 50 Euro, cent.
7,8 Euro, cent.
9
2
6
External Boiler Effi ciency
0 - 100%
90%
9
2
7
Energy Manager free parameter
9
2
8
Energy Manager free parameter
9
2
9
Energy Manager free parameter
9
3
Central Heating
9
3
0
CH pump prerun time
30 - 255 sec.
30 sec.
9
3
1
Time for prerun new attempt
0 - 100 sec.
90 sec.
9
3
2
CH pump overrun
0 - 15 min. ; 16 = sempre attiva
3 min.
9
3
3
Pump Speed Control
Low speed
High speed
Modulating
Modulating
9
3
4
Delta T Pump Setpoint
5°C - 20°C
5°C
9
3
7
Max PWM Pump
Min PWM pompa - 100%
100%
9
3
8
Min PWM Pump
80% - Max PWM pompa
100%
9
3
9
Floor drying Flow Set Point Temperature
25°C - 60°C
55°C
9
5
Domestic Hot Water
9
5
0
DHW Comfort Setpoint Temperature
35°C - 65°C
55°C
9
5
1
DHW Reduced Set Point Temperature
35°C - Comfort Setpoint Temperature
35°C
9
5
3
Comfort function
Disabled
Time Based
Always Active
Always Active
9
5
4
Tank charge mode
Standard
Only HP
Fast
Standard
9
5
5
Antilegionella Function
OFF - ON
OFF
9
6
Manual Mode - 1
9
6
0
Manual mode activation
OFF - ON
OFF
9
6
1
HP circulator control
OFF
Low Speed
High Speed
OFF
9
6
2
Diverter valve control
CH
DHW
DHW
9
6
4
Auxiliary circulator
OFF - ON
OFF