Chapter 1: Overview
Specifications
Quick Start Guide: 7000 Series 2 RU Data Center Switches
3
1.6
Specifications
Table 1-1
lists the specifications of Arista Data Center switches covered by this guide.
Table 1-1 Switch Specifications
Size (W x H x D)
DCS-7050SX-128
DCS-7050TX-128
DCS-7050SX2-128
DCS-7050TX2-128
DCS-7250QX-64
DCS-7260QX-64
DCS-7260CX-64
DCS-7260CX3-64
DCS-7280CR-48
DCS-7280CR2-60
DCS-7280CR2A-60
DCS-7280CR2K-60
48.3 x 8.8 x 45.9 cm (19 x 3.5 x 18.1 inches)
48.3 x 8.8 x 45.9 cm (19 x 3.5 x 18.1 inches)
48.3 x 8.8 x 45.9 cm (19 x 3.5 x 18.1 inches)
48.3 x 8.8 x 45.9 cm (19 x 3.5 x 18.1 inches)
44.5 x 8.8 x 55.3 cm (19 x 3.5 x 21.8 inches)
44.5 x 8.8 x 45.7 cm (19 x 3.5 x 18.0 inches)
44.5 x 8.8 x 45.7 cm (19 x 3.5 x 18.0 inches)
44.5 x 8.8 x 45.4 cm (19 x 3.5 x 17.9 inches)
44.5 x 8.9 x 56.3 cm (19 x 3.5 x 22.2 inches)
44.5 x 8.8 x 64.0 cm (19 x 3.5 x 25.2 inches)
44.5 x 8.8 x 64.0 cm (19 x 3.5 x 25.2 inches)
44.5 x 8.8 x 64.0 cm (19 x 3.5 x 25.2 inches)
Weight
DCS-7050SX-128
DCS-7050TX-128
DCS-7050SX2-128
DCS-7050TX2-128
DCS-7250QX-64
DCS-7260QX-64
DCS-7260CX-64
DCS-7260CX3-64
DCS-7280CR-48
DCS-7280CR2-60
DCS-7280CR2A-60
DCS-7280CR2K-60
15.1 kg (33 pounds)
15.6 kg (34 pounds)
15.1 kg (33 pounds)
15.6 kg (34 pounds)
19.2 kg (42 pounds)
16.1 kg (35.5 pounds)
21.3 kg (47 pounds)
15.6 kg (34 pounds)
21.2 kg (47 pounds)
24.9 kg (54.8 pounds)
24.9 kg (54.8 pounds)
24.9 kg (54.8 pounds)
Operating Temperature
Storage Temperature
Operating Altitude
Relative Humidity
all
all
all
all
0° to 40°C (32° to 104°F)
-25° to 70°C (-13° to 158°F)
0 to 3,000 meters (0 to 10,000 feet)
5 to 90%
Power Input (AC Power)
DCS-7050SX-128 / PWR-500AC
DCS-7050SX-128 / PWR-750AC
DCS-7050TX-128 / PWR-745AC
DCS-7050SX2-128 / PWR-500AC
DCS-7050TX2-128 / PWR-745AC
DCS-7250QX-64 / PWR-1100AC
DCS-7260QX-64 / PWR-1100AC
DCS-7260CX-64 / PWR-1900AC
DCS-7260CX3-64 / PWR-745AC
DCS-7260CX3-64 / PWR-1900AC
DCS-7280CR-48 / PWR-1900AC
DCS-7280CR2-60 / PWR-1900AC
DCS-7280CR2A-60 / PWR-1900AC
DCS-7280CR2K-60 / PWR-1900AC
100 - 240 VAC, 5.7-2.4 A, 50/60 Hz
100 - 240 VAC, 5.7-2.4 A, 50/60 Hz
100 - 240 VAC, 10-5 A, 50/60 Hz
100 - 240 VAC, 5.7-2.4 A, 50/60 Hz
100 - 240 VAC, 10-5 A, 50/60 Hz
200 - 240 VAC, 6.5 A, 50/60 Hz
200 - 240 VAC, 6.5 A, 50/60 Hz
200 - 240 VAC, 11.5 A, 50/60 Hz
100 - 240 VAC, 10-5 A, 50/60 Hz
100 - 240 VAC, 10-5 A, 50/60 Hz
200 - 240 VAC, 11.5 A, 50/60 Hz
200 - 240 VAC, 11.5 A, 50/60 Hz
200 - 240 VAC, 11.5 A, 50/60 Hz
200 - 240 VAC, 11.5 A, 50/60 Hz
Summary of Contents for DCS-7050SX-128