26
Tensor
7.2.2
Menu items in detail
7.2.2.1 Programming end positions
•
Select the menu item "EL" for programming the left end position or "ER" for the right end position and confirm with button
[M]. The screen displays a confirmation dialog.
E
.
L
E
.
t
•
Press button [R] (yes) to move to the new end position and confirm with button [M]. With button [L] (no), the process can
be aborted.
Motor or components may be damaged when driving on an obstacle. As long as the end
position is reprogrammed, the engine no longer stops at the predetermined end position.
For entering new end positions move the drive slowly and with caution
•
Move motor to the desired end position by pressing [L] or [R] .
•
Accept with button [M] the current position as end position. If programming is aborted by changing to AUTO mode, the
previously programmed end position applies.
For technical reasons the two end positions must be at least a 1/2 sensor turn apart. If the
difference range is too little, the controller gives out the error "RE" - "RangeError".
7.2.2.2 Set value input for the end positions
The left and right limit switch position is assigned to a new set value. Voltage or current values at the input terminals 51, 52 provide
the controller with the default for the positioning of the motor. The actual position signals the controller via the terminals 54, 55.
S
.
L
S
.
t
The input is suitably connected and configured via DIP switches 3 and 4, see page 20.
•
Select the menu item "SL" or "SR" and confirm with button [M]. Depending on DIP switch setting one of the following three
values will be displayed:
− DIP3/DIP4 – ON/OFF: 0 mA / 4 mA / 20 mA / 0…20 mA
− DIP3/DIP4 – OFF/ON: 0... 10 V
− DIP3/DIP4 – OFF/OFF: 0... 5 V
•
At preset of a
− current value (mA) select one of the displayed values
− voltage value (V) set a value between 0…5 or 0…10
CAUTION
ADVICE
!