• Unusual heavy development of
foam in the dirty water tank
• No cleaning agent is coming
out, even though the dispenser
button on the cleaning agent
attachment is being pressed.
• Is residual moisture to high,
liquid is no longer sucked up
properly
- Have you used the wrong type of shampoo?
Replace it
and only use the same type supplied with the appliance.
- Is there any cleaning liquid in the spraying agent tank?
Refill.
- Is the spray opening blocked?
Clean the nozzle with
hot water to remove any previous build up of impurities
(see “Cleaning the cleaning agent attachment”).
- Is the electronic suction power controller set to MIN?
Set suction power to MAX.
- Is the mechanical suction power controller on the hand
grip open?
Close the slider on the hand grip.
- Is the nozzle really flat on the floor?
Hold nozzle or
suction cleaning with a slightly greater incline.
GB