![Ariel JGJ Series Technical Manual Download Page 38](http://html1.mh-extra.com/html/ariel/jgj-series/jgj-series_technical-manual_2969706038.webp)
: JGW, JGR
AND
JGJ
S
ECTION
3 - S
TART
U
P
PAGE 3 - 4
Compressor Model ______________________ Serial No. F-______________________
YES
NO
36. Are the gas discharge temperature shutdowns installed,
set and working?
______ ______
37. Have the gas suction lines been blown out to remove
water, slag, dirt, etc.?
______ ______
38. Have temporary screens been installed at cylinder suction?
______ ______
39. Was compressor prelubed prior to starting? For electric
motor driven units, compressor must have prelube pump.
______ ______
40. For engine driven units, has the machine been rolled with the
starter to make sure it is free? The oil pressure should come up
noticeably while rolling on the starter.
______ ______
41. For other drivers, has the machine been barred over by hand to
ensure it is rolling free?
______ ______
42. Does the driver rotation match the compressor rotation arrow?
______ ______
43. For machines compressing a combustible gas, have the piping
and compressor been purged to remove all air?
______ ______
44. Have start-up instructions for other package equipment been
followed?
______ ______
45. Has the Packager’s representative done the required review of
the Packager’s Start-Up and Operating Instructions for the unit
with the unit operator?
______ ______
Check List - After Starting
YES
NO
1. Did the oil pressure come up immediately?
______ ______
2. Are the oil filter and force feed pump pressure gauges working?
______ ______
3. Oil filter diff. pressure <10 psi (69 kPa), unless otherwise specified?______ ______
4. Any strange noises or shaking in the compressor or piping?
______ ______
5. Is low oil pressure shutdown set at 35 psi (240 kPa)?
______ ______
6. Are the high discharge gas temperature shutdowns set at approx
10% above normal discharge temperature? 375°F (190°C) max.
______ ______
7. Is the distribution block indicator pin moving, and have you
set lubricator for proper break-in flow rate?
______ ______
8. Are there any oil leaks? If so, where?
______ ______
9. Are the scrubber dumps and high level shutdowns working?
______ ______
10. Are the scrubbers removing all liquids from the gas?
How often do they dump? (___minutes)
______ ______
11. Are there sands or oxides in the gas?
______ ______
12. Is the overspeed shutdown set?
______ ______
13. Are rod packings sealing properly?
______ ______
14. Have all safety functions been tested to ensure shutdown of unit
upon malfunction?
______ ______
Summary of Contents for JGJ Series
Page 30: ...FOR MODELS JGW JGR AND JGJ SECTION 1 DESIGN SPECIFICATIONS DATA PAGE 1 24 1 01 NOTES ...
Page 34: ...FOR MODELS JGW JGR AND JGJ SECTION 2 INSTALLATION PAGE 2 4 1 01 NOTES ...
Page 44: ...FOR MODELS JGW JGR AND JGJ SECTION 3 START UP PAGE 3 10 1 01 NOTES ...
Page 114: ...FOR MODELS JGW JGR AND JGJ SECTION 5 MAINTENANCE PAGE 5 42 1 01 NOTES ...
Page 120: ...FOR MODELS JGW JGR AND JGJ SECTION 6 TECHNICAL ASSISTANCE PAGE 6 6 1 01 NOTES ...
Page 130: ...FOR MODELS JGW JGR AND JGJ SECTION 7 APPENDICES PAGE 7 10 1 01 NOTES ...
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 141: ......