Compressor Model ______________________ Serial No. F-______________________
YES
NO
12. Have piston end clearances been checked with feeler gauges?
_____
_____
Record below:
Throw #1
#2
#3
#4
#5
#6
HE_______ _______ _______ _______ _______ _______
CE_______ _______ _______ _______ _______ _______
13. Has the crankcase been filled with oil to the proper level?
_____ ______
14. Has proper oil been installed if extreme ambient conditions
exist or special gases are compressed?
_____ ______
15. Is the compressor crankcase oil level control working and
set at the proper level?
_____ ______
16. Is the crankcase oil supply isolation valve open?
_____ ______
17. Does the crankcase low level shutdown work?
_____ ______
18. Have the recommended oil filter elements been installed?
_____ ______
19. Are the oil filter element and all lube oil piping primed with oil?
_____ ______
20. Is the low oil pressure shutdown installed and tubed correctly
to the downstream side of the oil filter?
_____ ______
21. Does the low oil pressure shutdown work?
_____ ______
22. Oil cooler? Compressor inlet oil temperature is 190°F (88°C) max. _____ ______
23. Is the crankcase oil temperature shutdown installed, set
and working?
_____ ______
24. If oil is cooled, is there a temperature control valve?
_____ ______
25. Is the crankcase breather element clean?
_____ ______
26. Is the force feed lubricator box filled with oil?
_____ ______
27. Is the force feed lubrication system primed?
_____ ______
28. Is the force feed lubrication system no flow shutdown
installed and working?
_____ ______
29. Is the force feed blow out assembly installed? Check rupture
disc for color? Purple is standard = 3250 PSIG (22 400 kPa).
_____ ______
30. Has the lubricator instruction plate or Technical Manual Cylinder
Lubrication Sheet been checked for proper lube feed rate?
_____ ______
31. Is there a working vibration shutdown mounted on compressor?
_____ ______
32. Are the primary and secondary packing vents and the distance
piece vents open, and when necessary, tubed off of the skid or
out of the building?
_____ ______
33. Is there some method of suction pressure control?
_____ ______
34. Are the suction pressure, interstage pressure and discharge
pressure shutdowns set and working?
_____ ______
35. Are the safety relief valves installed and working to protect
cylinders and piping for each stage of compression?
_____ ______
Summary of Contents for JGJ Series
Page 30: ...FOR MODELS JGW JGR AND JGJ SECTION 1 DESIGN SPECIFICATIONS DATA PAGE 1 24 1 01 NOTES ...
Page 34: ...FOR MODELS JGW JGR AND JGJ SECTION 2 INSTALLATION PAGE 2 4 1 01 NOTES ...
Page 44: ...FOR MODELS JGW JGR AND JGJ SECTION 3 START UP PAGE 3 10 1 01 NOTES ...
Page 114: ...FOR MODELS JGW JGR AND JGJ SECTION 5 MAINTENANCE PAGE 5 42 1 01 NOTES ...
Page 120: ...FOR MODELS JGW JGR AND JGJ SECTION 6 TECHNICAL ASSISTANCE PAGE 6 6 1 01 NOTES ...
Page 130: ...FOR MODELS JGW JGR AND JGJ SECTION 7 APPENDICES PAGE 7 10 1 01 NOTES ...
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 141: ......