A Series User’s Manual
41
Resetting Printer to Factory Defaults
1. Turn on the printer and wait till both "Ready" indicator and
"Power" indicator stay solid green.
2. Press the "Feed" button for 5 seconds, and the "Ready"
indicator and "Power" indicator will go off in order.
(at this step, if the “FEED” button is pressed for 10 seconds,
printer will reset first >> feed blank labels as media
calibration >> and then print configuration/ self-test labels.)
3. Once "Power" indicator becomes lit again, release the
FEED button.
4. "Ready" indicator will then become lit, too. At this moment,
the printer has resumed its factory default settings
Note:
Revise the factory default settings that stored in flash, even
if turn off the power source cannot be eliminated.
A Series User’s Manual
42
Sensor Detection
Detection Area of the Transmissive Sensor (edge)
The Transmissive Sensor (edge) is positioned at 7.7mm from the
left edge of media.The detection area, as illustrated below.