background image

 

E

N 50123793

 20

13/06

 

W

e r

es

er

ve the 

right to 

m

ak

e tec

hni

cal

 c

hanges

 

IT 1911i 

Industrial 2D-code hand-held scanner  

with RF transmission 

 

 
 

 

TECHNICAL DESCRIPTION 

 

Summary of Contents for 1910i

Page 1: ...EN 50123793 2013 06 We reserve the right to make technical changes IT 1911i Industrial 2D code hand held scanner with RF transmission TECHNICAL DESCRIPTIO N ...

Page 2: ... 2013 Leuze electronic GmbH Co KG In der Braike 1 D 73277 Owen Germany Phone 49 7021 573 0 Fax 49 7021 573 199 http www leuze com info leuze de ...

Page 3: ... 2 Reading fields 9 4 Resetting the IT 1911i to factory settings 10 5 Configuration 11 5 1 IT 1911i to the serial PC interface 12 5 1 1 With KB 232 1 IT190x Part no 50114517 12 5 1 2 Configuration for the Leuze standard protocol 13 5 2 IT 1911i to MA 200i 14 5 2 1 Commissioning 14 5 3 IT 1911i to MA 21 17 5 4 IT 1911i to PS2 interface 19 5 5 IT 1911i to USB interface keyboard emulation 20 5 6 IT 1...

Page 4: ...8 Service and support 27 Leuze electronic IT1911i 4 ...

Page 5: ...installed 3 Package insert 1 2 Base station IT 1911i 1 Base station CCB02 100BT An overview of the types can be found on page 24 For accessories see page 25 Type designation Information about standards Information about standards Laser notice Scanner reading field Leuze electronic IT1911i 5 ...

Page 6: ...o place 2 Connect the other end of the connection cable to the appropriate connection socket on the PC 3 You may need a power supply unit for voltage supply if you would like to charge the hand held scanner at the base station or if you use an RS 232 interface Use the pin assignments see page 8 to select the appropriate cable for your application 4 Connect the power supply unit to the power socket...

Page 7: ...ght angle to the bar code The green LED line which serves as an alignment aid should be positioned at the center of the code This ensures that the center point of the camera is aligned with the code The scanner will not be able to detect the label correctly if it is not fully captured by the camera The green LED line is smaller and narrower if the scanner is held closer to the code Small codes sho...

Page 8: ... connection For the suitable power supply unit for IT 190x 100 230 V 50 60 Hz see chapter 7 The power supply unit connection on the cable is not used 3 1 2 KB PS2 1 IT190x Part no 50114519 Helix cable maximum length 3 m Pin assignments of the Mini DIN socket or connector for cable CBL 720 300 C00 Pin connector Pin socket Signal Designation 1 PC Data PC data line 2 2 NC Not used 3 3 GND Ground conn...

Page 9: ...ith part no 50114521 but helix cable maximum length 5 m 3 2 Reading fields IT 1911i ER 3 Code 39 5 mil 0 127 mm UPC 13 mil 0 330 mm Code 39 20 mil 0 508 mm PDF 417 6 7 mil 0 170 mm Data Matrix 10 mil 0 254 mm QR Code 20 mil 0 508 mm Typ reading distance 1 mm 1 Dependent on code module Leuze electronic IT1911i 9 ...

Page 10: ...below Attention All settings are lost Return the IT 1911i to the base station so that the settings can be accepted Successful reading is confirmed by an acoustic signal and the red LED on the base station going out briefly You may then continue making settings or operation of the device Leuze electronic IT1911i 10 ...

Page 11: ...the hand held scanner with the USB and RS 232 interfaces with the aid of the VisualXpress PC program You can download and install this program from our homepage at www leuze com The program can be used to make settings and transfer them to the hand held scanner The configuration can also be stored so that it can be reused at a later time The standard applications are described and summarized below...

Page 12: ... 50122434 IT 1911i ER 3 1x 50122431 Base station IT 1911i 1x 50114517 KB 232 1 IT 190x 1x 50123862 Power supply unit RS 232 transmission with 115200 baud 8 data bits 1 stop bit no parity suffix CR LF Return the IT 1911i to the base station so that the settings can be accepted Successful reading is confirmed by an acoustic signal and the red LED on the base station going out briefly Leuze electroni...

Page 13: ... To configure the device please scan the codes in the specified order Successful reading is confirmed by an acoustic signal and the red LED on the base station going out briefly RS 232 baud rate 9600 Prefix STX Suffix CR LF Alternatively the following Aztec configuration code can also be used The individual pieces of bar code information are again provided in succession in the Aztec configuration ...

Page 14: ...50112892 MA 208i Ethernet gateway or 50112891 MA 248i Profinet gateway 5 2 1 Commissioning Open the MA 200i Guide KB JST HS 300 with the PG cable gland through the threaded hole and insert the 12 pin JST connector Connect the base station with the RS 232 cable Connect the RS 232 cable to the 9 pin D sub connector Set the address using the address switch Insert the field bus connection cable Apply ...

Page 15: ...1i KB JST HS 300 approx 0 3 m 9 pol D sub 18 to 30 V DC Details on connecting the MA 200i can be found in Technical description MA 200i NOTICE You can find the configuration codes on the next page Leuze electronic IT1911i 15 ...

Page 16: ... confirmed by an acoustic signal and the red LED on the base station going out briefly RS 232 baud rate 9600 Suffix CR LF Alternatively the following Aztec configuration code can also be used The individual pieces of bar code information are again provided in succession in the Aztec configuration code Return the IT 1911i to the base station so that the settings can be accepted This procedure is co...

Page 17: ...34 IT 1911i ER 3 1x 50122431 Base station IT 1911i 1x 50114517 KB 232 1 IT190x 1x 50123862 Power supply unit 1x 50035421 KB 021 Z 1x 50030481 MA 21 100 5 3 1 1 Pin assignments KB021 Z Core color Signal Terminal assignments MA 21 brown RXD 26 white TXD 27 blue GND 28 red VCC black GND bare shield PE 21 Leuze electronic IT1911i 17 ...

Page 18: ...acoustic signal and the red LED on the base station going out briefly RS 232 baud rate 9600 7 data bits even parity 1 stop bit Suffix CR LF Alternatively the following Aztec configuration code can also be used The individual pieces of bar code information are again provided in succession in the Aztec configuration code Return the IT 1911i to the base station so that the settings can be accepted Th...

Page 19: ...62 Power supply unit Please connect the base station acc to the figure below To do this proceed as follows 1 Switch off the PC 2 Unplug the keyboard 3 Connect the cable for the base station between the keyboard and the PC 4 Switch the PC back on 5 Scan the code shown below NOTICE To charge the IT 1911i the power supply unit must be plugged in and the hand held scanner placed in the base station 5 ...

Page 20: ...190x or 50114523 KB USB 2 IT190x 1x 50123862 Power supply unit Please connect the base station acc to the figure below To do this proceed as follows 1 Connect the cable for the base station to a free USB port 2 The scanner acknowledges this connection with an acoustic signal 3 Scan the code shown below NOTICE To charge the IT 1911i the power supply unit must be plugged in and the hand held scanner...

Page 21: ...KB USB 1 IT190x or 50114523 KB USB 2 IT190x 1x 50123862 Power supply unit Please connect the base station acc to the figures below To do this proceed as follows 1 Install the USB serial driver for the IT 1911i 2 Connect the cable for the base station to a free USB port 3 The scanner acknowledges this connection with an acoustic signal 4 Scan the code shown below 5 Open a terminal program or your p...

Page 22: ...port emulation only The command is to be sent at the set baud rate parity and data and stop bits The activation command is SYN T CR ASCII decimal values 022 084 013 To cancel read readiness send a deactivation The deactivation command is SYN U CR ASCII decimal values 022 085 013 Following a successful read operation the IT 1911i deactivates itself The second option is to use the trigger button to ...

Page 23: ...able using a small pin the connector is unlocked 5 If even after performing all of these measures the scanner is not ready for operation replace the power supply unit with a different recommended power supply unit which you are certain functions properly 6 Make certain that your scanner s interface is compatible with the PC Further information on this topic can be found in the manual for your PC A...

Page 24: ... codes 50122434 IT 1911i ER 3 Bluetooth class 1 Base station with communication and charging function 50122431 Base station for IT 1911i Bluetooth class 1 PS2 USB TTL RS 232 All devices are supplied without cable Cables must be ordered separately see chapter 7 Accessories Spare parts Leuze electronic IT1911i 24 ...

Page 25: ...4517 KB 232 1 IT 1900 RS 232 cable for IT 190x 3 m spiral CBL 020 300 C00 X 50123862 NT Base IT 1911i Voltage supply for the base station 5 V DC RS 232 cable and base station 1 8 m straight PS 05 1000W C X 50105384 Battery for IT 1911i 3820 4820 and IT 6320 3 7 V 2000 mAh 100000495 X 50114494 BAT Charger 4 Desk EU Charging station with power supply unit for up to 4 batteries 2 x 1 5 m straight MB4...

Page 26: ...n cable MA xx to IT 1911i Part no 50035421 7 2 Connection to various fieldbuses using MA 200i MA 204i Profibus gateway Part no 50112893 or MA 208i Ethernet gateway Part no 50112892 or MA 248i Profinet gateway Part no 50112891 KB JST HS 300 Connection cable MA xx to IT 1911i Part no 50113397 Leuze electronic IT1911i 26 ...

Page 27: ... hotline 49 0 7021 573 123 Monday to Thursday 8 00 a m to 5 00 p m UTC 1 Friday 8 00 a m to 4 00 p m UTC 1 E mail service identify leuze de Return address for repairs Service center Leuze electronic GmbH Co KG In der Braike 1 D 73277 Owen Germany Leuze electronic IT1911i 27 ...

Reviews: