V 11/17
58
1. Remove the cover of the terminal block on the right side of the outdoor unit. (one screw)
2. Connect the wires to the unit as shown in the figure, make sure that each cable is properly
connected to the terminal boards of the two units.
3. Reassemble the cover of the terminal
Insert a magneto thermic switch
with sufficient power and
observe the following table:
Power circuit breaker
14K - 10A
To protect the unit against short circuits,
mount on the power line amagneto
thermalomni polar switch (IG) curve C
250V with a minimum contact opening of
3mm.
Wrong connection of cable may cause
malfunctions
of
the
electrical
components.Once fixed the cables, make
sure that the lines between the links and
the fixing point are separated by some
space
The connection pipes and connection
cables of units A and unit B must
correspond to each other.
The device must be installed in
accordance with national regulations of
wiring.
Handle
Front
side plate
To the power supply
To unit B
Power cord
To unit A
connecting
cable
L
connecting
cable