1
1
2
2
5
5
3
3
4
4
INDOOR UNIT
Open the front panel;
Remove the screw from electrical box cover, pull the
electrical box cover away from the unit and set aside.
Remove the screw from fastener, pull the fastener
away from the unit and set aside.
Connect the cable.
Replace the fastener and electrical box cover.
Indoor unit terminal
Screw
Connecting cable
Diagram
1
1
1
2
2
INSTALLATION
Secure the mounting plate
The mounting plate should be attached to the structural part of wall (post etc.).
fasten string at the central hole
175mm or more
from sidewall
245mm or more
at least 60mm
from sidewall
mounting plate
plumb
NOTICE
The holes at solid arrow position must be secured to avoid the shake of mounting plate.
When the expansion bolts are used, two holes ( 11
20 or 11 26 ) that the distance
between them is 450mm should be adopted.
Drill on the wall
Confirm the position of holes, and drill holes of 65mm on the wall.
°²
×°
˵
Ã÷
65mm
12mm
12mm
12mm
12mm
28mm
28mm
12mm
12mm
Left rear piping
right rear piping
Indoor unit
terminal
Fastener
Connecting cable
Electrical box cover
Screw
Pull the connecting cable's
wire in completely
Center
Center
3
3
Wiring
65mm