Argo AGE52RH U.E. Owner'S Manual Download Page 14

If problems can not be corrected after  doing  below  items, please 
stop the air conditioner, contact our air conditioner specially eng-
aged service centre nearest to you to get help. 

Is there a fault ?     

  Fault analysis

Air conditioner does 
not operate at all.

Does power fail ? 
Is plug out ? 
Does power fuse or switch off ? 
Is  voltage higher  than 253 V  or  lower  than 
207V? 
Is  time set suitable? 

Remote controller is not 
available and  does  not 
display.

It  is  not  running 
after  I/O  button 
is pressed.

Cooling and heating 
efficiency is not good.

Air will not immediately 
blow out at the start 
of HEAT mode.

It is processing information, air will only  blow 
out  when sufficiently warm. Please wait.

This  is  a way to protect  compressor as  per   
microprocessor  instructions.  Please  wait  3 
minutes.

Does temperature set suitably ? 

Are filters dirty? 

Are inlets and outlets of outdoor unit blocked? 

Does sleep function start during daytime?

Does indoor fan speed set  low ? 

Are doors and windows closed ? 

If  disturbed  abnormally  or operation modes 
changed  too frequently, sometimes the  rem-
ote  controller  would  lose function.  Please 
plug out and plug in again, it may be ok.
If  remote controller displays unclear or disp-
lays all symbols, please change batteries.

FAULT CONFIRMATION AND ANALYSIS

Summary of Contents for AGE52RH U.E.

Page 1: ...k you for choosing an Air Conditioner Please read this OWNER S MA NUAL carefully prior to using keep it for further reference OWNER S MANUAL SPLIT AIR CONDITIONER WALL MOUNTED TYPE AGW52RH U I AGE52RH...

Page 2: ...or Parts Safety Awareness Operation procedure Remote Controller s Preparative Before Operation Operation Explanations of Air Conditioner Service and Maintenance of the Air Conditioner Fault Confirmati...

Page 3: ...ulti hole sockets Possible fire electric shock may occur for poor connection bad insulation and excessive allowable current Do not plug power cable when in operation Spark may appear and cause fire Pu...

Page 4: ...oors and windows better using cont ains while operating air conditioner for a long time if room air is quite turbid you should open a door and window for a moment to get some outdoor fresh air Do not...

Page 5: ...ir inlet Manual operation open the Front panel INDOOR UNIT Time indicator Sleep indicator Run indicator Power supply cord Deflector Left Right deflector SWING SWING MANUAL MANUAL OFF OFF ON ON CANCEL...

Page 6: ...T BUTTON RUN STOP BUTTON FAN SPEED BUTTON SLEEP BUTTON RESET PIECE TIME SET BUTTON TIME CANCEL BUTTON TIME ON BUTTON TIME OFF BUTTON OPERATION MODE BUTTON MANUAL SWING BUTTON SWING BUTTON NOTICE REMOT...

Page 7: ...ly short two RESET piece it will operate normally Remove batteries if Remote controller has not been used for a long time When the button is pressed indoor unit will beep once or twice indicating the...

Page 8: ...er s display Sleep selection Press SLEEP button set sleep operation and cancel when repressed 3 3 Fan speed adjustment Press FAN SPEED button change the fan speed of indoor unit in the order of low me...

Page 9: ...ngers Fig 1 Left Right deflector ADVICE In DRY or COOL mode advise to make the Fan speed with auto air blows downward in 1 In HEAT mode advise to make the Fan speed with auto air blows downw ard in 4...

Page 10: ...e Press MAUNAL SWING button or SWING button to change up down air flow direction Press FAN SPEED button to change the fan speed of indoor unit Press TEMPERATURE ADJUSTMENT button to change the setting...

Page 11: ...nter time setting press button or button Untill set time and timer operation goes off press If you want or will disappear on the remote controller display ON Press button Remote Controller display whe...

Page 12: ...ed dirt may cause fire FAN OPERATION Take the batteries out of the remote controller Want to use the Air Conditioner Clean filters and replace them to origi nal position Clean indoor unit with soft cl...

Page 13: ...then push down and close front panel Clean deodorization filters and air cleaner Take out filters first then take out deodorization filter and air cleaner Clean deodorization filter air clean er with...

Page 14: ...Air will not immediately blow out at the start of HEAT mode It is processing information air will only blow out when sufficiently warm Please wait This is a way to protect compressor as per microproc...

Page 15: ...opping on the heat exchanger Melting sounds of frost on heat exchanger Indoor unit issue pooosh sound and click sound Click sound of fan or compressor when switc hing ON OFF pooosh sound of refrigeran...

Page 16: ...cting cable is damaged it must be replaced by the manufacturer or its service agent or similar qualified person in order to avoid a hazard C Indoor side DB WB Maximum cooling Minimum cooling Maximum h...

Page 17: ...hose high front right back underside left back left back Configuring pipe can be installed to back right underside or left back side Cover connecting pipe with heat isolating material the thickness o...

Page 18: ...m wall to avoid any vibr ation Avoid direct sunshine Easy to drain condensate water Do not make any interference caused by the fluorescent lamp to the remote controller s signal Minimum distance betwe...

Page 19: ...of wall post etc fasten string at the central hole 175mm or more from sidewall 245mm or more at least 60mm from sidewall mounting plate plumb NOTICE The holes at solid arrow position must be secured t...

Page 20: ...owed after refit it would lead to water leak Arrangement of drain hose To eject the condensate water easily the drain hose should be declined downward The arrangement in diagram2 5 is wrong If the dra...

Page 21: ...e The connecting cables must be clipped together 1 7 7 Wiring 1 1 1 Flaring the pipe end 1 2 2 Cut the pipe using a pipe cutter Raughness Remove burrs at the tip of the pipe cut Reamer Burr Insert a f...

Page 22: ...ench Fig 2 Open the valve of the low pressure and close high pressure valve of manifold gauge Purge the air from the system using the vacuum pump until its pressure low pressure side is below 12Pa Clo...

Page 23: ...nly type add amount A Lm 7m 15g m Heat pump type add amount A Lm 7m 50g m A add refrigerant amount L the length of connecting pipe 1 4 4 7 0 0 8 15 50 9 30 100 10 45 150 the length of connecting pipe...

Page 24: ...Via Varese 90 21013 Gallarate VA Italy Phone 39 0331 755 111 Fax 39 0331 766 240 www argoclima com...

Reviews: