Before installation, inspect the following accessories:
Installation Instructions
Location of indoor unit
Airflow can not be blocked.
Good ventilation, low dust,avoids rain
or direct sunshine.
Operation noise or air blowing out will
not affect neighbors' comfort.
Firmly mounted on rack,which will red-
uce noise and vibration.
Avoid places close to inflammable
gas leakage.
Unit must be mounted firmly when
installed high up.
Not to be affected by strong wind.
Cooled or heated air should be blown
to every art of the room.
Maximum height between indoor/out-
door units is 5m.
Mount on firm wall to avoid any vibr-
ation.
Avoid direct sunshine.
Easy to drain condensate water.
Do not make any interference caused
by the fluorescent lamp to the remote
controller's signal.
Minimum distance between air condi-
tioner and home appliance( TV/ Radio
etc. ) is 1m.
Location of outdoor unit
INSTALLATION ACCESSORIES
1
A
1
4
2
B
5
1
3
C
5
3
4
D
2
5
5
E
2
6
F
1
7
G
2
1
8
H
1
1
9
I
1
1
10
J
1
1
Indoor unit accessories
Mounting plate
Tapping screw ST4
25
Expansion rubber plug
Expansion bolt
Battery
Remote controller
Felt
Adiabatic underlay
connecting cable+signal wire
Deodorization air
cleaner
Quantity
Quantity
Installation accessories
Connecting pipe screws
Bonding tape
Clamp
Cement nail
Drain hose
Opening cap
Wall-hole cover
Indoor wall-hole cover
putty
Airproof oil
1+1