26
13
NTT A (Wide Tube
Temperature)
sensor fault.
Compressor and fan
are stopped.
The system restarts
as soon as the
sensor is repaired.
Sensor out of order or
disconnected (check
wiring diagram).
Reconnect or replace the sensor.
14
NTT B (Wide Tube
Temperature)
sensor fault.
Compressor and fan
are stopped.
The system restarts
as soon as the
sensor is repaired.
Sensor out of order or
disconnected (check
wiring diagram).
Reconnect or replace the sensor.
15
or
100
Wrong selection of
indoor units
combined with the
outdoor unit.
Compressor and fan
are stopped.
The selection of the
indoor units connected
to the outdoor unit is
not allowed.
Check for the allowed combinations.
Choose a correct indoor-outdoor units
combination.
101
Test Mode error (at
factory only).
Compressor and fan
are stopped.
Unit is running the
factory test mode
routine.
Cycle the power supply to the normal
functioning.
Summary of Contents for AEI1G 42 EMX
Page 27: ...27 13 Component replacement FRONT RIGHT LEFT AND REAR PANEL ...
Page 28: ...28 ...
Page 29: ...29 CONTROL AND EXPANSION BOARD remove the right the left the front and the rear panel ...
Page 30: ...30 ...
Page 31: ...31 ...
Page 32: ...32 COMPRESSOR remove the right the left the front and the rear panel ...
Page 33: ...33 EXPANSION VALVE remove the right the left the front and the rear panel ...
Page 34: ...34 FAN MOTOR remove the right the left the front and the rear panel ...
Page 36: ...36 15 Labels Energy labels AEI1G 42 EMX ...
Page 37: ...37 AEI1G 50 EMX Energy labels ...
Page 38: ...38 Rating labels ...
Page 39: ... ARGOCLIMA SPA Via Alfeno Varo 35 Alfianello BS Italy ...