![Argo AEI1G 42 EMX Technical Data & Service Manual Download Page 19](http://html.mh-extra.com/html/argo/aei1g-42-emx/aei1g-42-emx_technical-data-and-service-manual_2967447019.webp)
19
10
Component description
type
HERMETIC, TWIN ROTARY, DC INVERTER
model
SNB110FGYMT
oil
FV 50S
refrigerant
R410A
motor
BRUSHLESS MOTOR
n. of poles
6
rated output
750W
winding resistance
(@20 °C)
U-V: 0,58 Ω
V-W: 0,58 Ω
U-W: 0,58 Ω
overload protector
EXTERNAL
type
HERMETIC, TWIN ROTARY, DC INVERTER
model
SNB130FGBMT
oil
FV 50S
refrigerant
R410A
motor
BRUSHLESS MOTOR
n. of poles
6
rated output
900W
winding resistance
(@20 °C)
U-V: 0,98 Ω
U-V: 0,98 Ω
U-V: 0,98 Ω
overload protector
EXTERNAL
Fan Motor
model
ZW465B57
motor
BRUSHLESS MOTOR
n. of poles
8
rated output
20 W
rpm
variable, 200 ÷ 850
winding resistance
(@25 °C)
BRN (W) - BLK (U) :
206 Ω
WHT (V) - BLK (U) :
206 Ω
BRN (W) - WHT (V) :
206 Ω
4-way Valve
model
SHF-7K-34U (valve) - SHF-4-10L3 (coil)
coil rating
AC 220-240V 50/60Hz
coil resistance
1440 Ω ± 7% at 20°C
Electronic Expansion Valves
model
CAM-BD15EX-1 (valve) - ZCAM-MD12EX-9M-B (coil)
coil rating
DC 12V
coil resistance
46 Ω ± 4% at 20°C
Compressor AEI1G 42 EMX
Compressor AEI1G 50 EMX
Summary of Contents for AEI1G 42 EMX
Page 27: ...27 13 Component replacement FRONT RIGHT LEFT AND REAR PANEL ...
Page 28: ...28 ...
Page 29: ...29 CONTROL AND EXPANSION BOARD remove the right the left the front and the rear panel ...
Page 30: ...30 ...
Page 31: ...31 ...
Page 32: ...32 COMPRESSOR remove the right the left the front and the rear panel ...
Page 33: ...33 EXPANSION VALVE remove the right the left the front and the rear panel ...
Page 34: ...34 FAN MOTOR remove the right the left the front and the rear panel ...
Page 36: ...36 15 Labels Energy labels AEI1G 42 EMX ...
Page 37: ...37 AEI1G 50 EMX Energy labels ...
Page 38: ...38 Rating labels ...
Page 39: ... ARGOCLIMA SPA Via Alfeno Varo 35 Alfianello BS Italy ...