![Argo ACS100PH Technical Data & Service Manual Download Page 129](http://html.mh-extra.com/html/argo/acs100ph/acs100ph_technical-data-and-service-manual_2967427129.webp)
5
5
- 5
*2:
7-segment, 4-digit display for remote controller timer display
The connected unit Nos. are displayed as shown below, using the 7-segment 4-digit (
:
) display and the
colon.
—
—
—
—
—
—
—
—
1
2
7
12
17
3
13
18
8
4
14
19
9
5
10
15
20
6
11
16
21
22
27
32
37
23
33
38
28
24
34
39
29
25
30
35
40
26
31
36
Display for unit Nos. 1 – 20
●
Display for unit Nos. 21 – 40
●
●
●
Not lit
Lit
Not lit
Lit
Not lit
Lit
Not lit
Lit
• Display of unit No. 1
• Display of unit Nos. 1 and 2
• Display of unit Nos. 1, 2, and 3
• Display of unit Nos. 1, 2, 3, and 4
Not lit
Lit
Not lit
Lit
Not lit
Lit
Not lit
Lit
Meaning of display colon
Meaning of display colon
is not displayed.
The meaning of the colon display changes in the same way, allowing unit Nos. up to 80 to be displayed.
Sample displays of the unit Nos. of connected indoor units
The colon display changes automatically every 10 seconds.
(The display does not change if higher unit numbers do not exist.)
Pressing the
button switches the display immediately to the next higher level, even if 10 sec-
onds have not passed.
*3:
The total compressor operating time is displayed
(in 1-hour units) using 8 digits.
• When the first 4 digits are displayed, the top
point of the colon is lit.
• When the last 4 digits are displayed, the colon
points are not lit.
• The display of the first 4 and last 4 digits
changes automatically every 10 seconds. It can
also be changed by pressing the
button.
NOTE
With the outdoor unit maintenance remote controller (when connected to the outdoor unit), the unit remote con-
troller check functions will not operate.
NOTE
(A) and (B) are displayed alternately.
A
B
10: <Total compressor operating time>
04-309 Sanyo-5 10/27/04 1:51 PM Page 5
Summary of Contents for ACS100PH
Page 95: ...3 3 2 3 1 Indoor Units Wall Mounted Type AWS36PH Electric Wiring Diagram ...
Page 96: ...3 3 3 3 1 Indoor Units Wall Mounted Type AWS36PH Schematic Diagram ...
Page 97: ...3 3 4 3 1 Indoor Units Wall Mounted Type AWS71PH Electric Wiring Diagram ...
Page 98: ...3 3 5 3 1 Indoor Units Wall Mounted Type AWS71PH Schematic Diagram ...
Page 99: ...3 3 6 3 2 Outdoor Units Electric Wiring Diagram AES71PIC ...
Page 100: ...3 3 7 3 2 Outdoor Units Schematic Diagram AES71PIC ...
Page 101: ...3 3 8 3 2 Outdoor Units Electric Wiring Diagram AES71PIH ...
Page 102: ...3 3 9 3 2 Outdoor Units Schematic Diagram AES71PIH ...
Page 103: ...3 3 10 3 2 Outdoor Units Electric Wiring Diagram AES100PIC ...
Page 104: ...3 3 11 3 2 Outdoor Units Schematic Diagram AES100PIC ...
Page 105: ...3 3 12 3 2 Outdoor Units Electric Wiring Diagram AES100PIH ...
Page 106: ...3 3 13 3 2 Outdoor Units Schematic Diagram AES100PIH ...
Page 107: ...3 3 14 3 2 Outdoor Units Electric Wiring Diagram AES125PIC ...
Page 108: ...3 3 15 3 2 Outdoor Units Schematic Diagram AES125PIC ...
Page 109: ...3 3 16 3 2 Outdoor Units Electric Wiring Diagram AES125PIH ...
Page 110: ...3 3 17 3 2 Outdoor Units Schematic Diagram AES125PIH ...