Subject to change · V 0.1 · 02.2020 · EN
Page 30
www.argo-hytos.com
15.3 Operating conditions
Permissible temperature range
Hydraulic fluid °C
0 ... 65 (note viscosity range)
Ambient temperature °C
0 ... 50
Risk of burns
Contact temperatures according to DIN EN563 (3) and DIN EN13202 (4) may be
exceeded during operation.
›
Allow the filter unit to cool down before touching it.
Electric drive
Continuous operation min.
[mm
2
/s]
Continuous operation max.
[mm
2
/s]
Short-term operation
[mm
2
/s]
1 ~ Motor, 230 V
15
600
800
3 ~ Motor, 400 V
15
600
800
NOTE
Varying viscosity behavior
›
Viscosities of a medium are always temperature-dependent.
Admissible suction heights
m (max.) first use / unfilled
2,0
m (max.) operating status
6,0
Media resistance
Resistant to environmentally friendly and mineral oil based fluids.
Before use with synthetic fluids please contact the manufacturer.
Work position
vertical
Mains fuse
FNAPC1 045-XXXX
23050
-X-X
1 ~ Motor, 230 V / 50 Hz, 1.1 KW
16 Ampere
FNAPC1 045-XXXX
40050
-X-X
3 ~ Motor, 400 V / 50 Hz, 1.1 KW
16 Ampere
15.4 Hydraulic circuit diagram
Fig. 14.1: Hydraulic circuit diagram - measurement before filter
CAUTION
Fig. 14.2: Hydraulic circuit diagram - measurement after filter