Subject to change · UMPC 045_31168300 · 0717 · EN
Page 28
www.argo-hytos.com
10.6 Monitoring modes
After switching on the device,
two modes
are available:
10.6.1 Continuous measurement without automatic shutdown (Mode 1)
The sensors are started directly after switching on the pump.
A rinsing time of the sensor system of 3 minutes is started.
After the flushing time, the actual cleanliness control begins.
The measured values are then output on the display.
10.6.2 Measurement with cleanliness class specific shutdown (Mode 2)
Fig. 21: Automatic shutdown menu
When the automatic mode is active, "AUTO" appears on the
main screen.
The cleanliness classes must be reached three times for shut-
down.
Only then the device switches off automatically.
Fig. 22: Automatic active
After the initialization screen (page 19, Fig. 12) has been
displayed, press the "Hook" button to enter the
"Automatic shutdown menu".
The desired cleanliness class can be set under ISO: - / - / -.
These set values represent the ISO class to be achieved.
It is also possible to set the measuring times and the break times
of the sensors.
The flushing time is at least 3 min.
After setting the required parameters leave the menu with "X".
When switched off, an additional display appears, which lists the
following items:
ISO : --/ -- /-- = Cleanliness class on shutdown
Date
Time of day
TRun = Runtime until shutdown
The "RESET" light is also illuminated and the orange LED on the
display flashes.