background image

 

Audio Resource Group, Inc. • 405 Main Ave W, Unit 4G • West Fargo, ND 58078 • ©2016 Audio Resource Group, Inc. • All Rights Reserved 

www.argaudio.com

 

Page 2 

CONTROL FUNCTIONS:  

 

The buttons on the receiver perform the functions as detailed below: 

 
1.    Channel Up Button 

6.    Set Button 

12.    Screw 2 (Used to change the 
headphone jack) 

2.  Channel Down Button 

7.    Delete Button 

13.    C-SAFE Port (Vin Power in) 
 
 

3.  Volume Up Button 

9.    Memo Button 

14.    Replaceable headphone jack 
module 

4.  Volume Down Button 

10.    Mute Button 

15.    Auto Power ON/OFF and 
3.5mm Stereo Audio Jack. 

5.  Mode Button 

11.    Screw 1 (Used to change the                
headphone jack) 

   

MOUNTING INSTRUCTIONS: 

 

The  ARG  900MHz  receiver  is  a  universal  unit  designed  to  be  compatible  with  most  makes  and  models  of  cardio 
equipment. To mount the Receiver:  
1. Determine the appropriate location to mount the receiver to the cardio equipment. Take note the range of motion of 
the  components  of  machine  and  make  sure  the  placement  of  the  receiver  and  its  cabling  will  not  interfere  with 
operation of the machine or any safety features.  
2. Slide the cable ties through the appropriate holes in the mounting cleat on the underside of the receiver. (Top to 
bottom if you are mounting it to a horizontal bar or side to side if you are mounting to a vertical bar.)  
3. Wrap and thread the cable ties around the bar on the cardio machine at the predetermined location. Pull the ties 
tightly around the bar so the receiver does not move or rotate. Be careful not to over-tighten the ties to avoid cracking 
the mounting cleat or case of the receiver. Trim off the excess ends of the cable ties.  
4.  Connect  the  power  cable  to  the  receiver.  The  receiver  can  be  powered  by  either  a  CSAFE  power  outlet  on  the 
cardio machine or an A/C power converter that can be plugged into the wall/floor. (Power adapters and cables are not 
included and must be ordered separately.) If you are using a C-SAFE connection: connect one end of the Cat-5 cable 
to the C-SAFE port on the cardio machine. (Check with the equipment manufacturer to make sure the machine has 
this feature and for location of the outlet.) The other end of the cable connects to the RJ45 receptacle on the  back of 
the receiver. If you are using an A/C power supply: locate a standard 110V outlet and plug the 12V A/C adapter side 
into the outlet and the RJ45 plug into the receptacle on the back of the receiver. Make sure to route the cord for either 
option appropriately to avoid interference with any of the functions or safety features of the cardio machine. 

Note: Once mounted, the receiver can be rotated by lifting the main unit away from the cardio equipment and 
rotating it to the desired angle.  It will lock back down on its own.  Verify that the unit is locked correctly by 
gently turning the unit to the right or left. 

Summary of Contents for ARG-900-RX-YF

Page 1: ...oup Inc 405 Main Ave W Unit 4G West Fargo ND 58078 2016 Audio Resource Group Inc All Rights Reserved www argaudio com Fitness Entertainment Solutions 900 MHz Analog Receiver Manual and User Guide ARG 900 RX YF OM015RevA ...

Page 2: ...able ties around the bar on the cardio machine at the predetermined location Pull the ties tightly around the bar so the receiver does not move or rotate Be careful not to over tighten the ties to avoid cracking the mounting cleat or case of the receiver Trim off the excess ends of the cable ties 4 Connect the power cable to the receiver The receiver can be powered by either a CSAFE power outlet o...

Page 3: ...are broadcasting or if you are in an area with excessive noise or interference you can adjust the scanning sensitivity of the receiver To adjust the sensitivity press the Delete button while in the programming mode Each time you press the button the sensitivity setting will advance by 1 strength 16 total strengths 0 to F The higher the number or letter the less sensitive the scan will be The facto...

Page 4: ...is powered up the display will flash the number cycles the module has used under the letters UHF The headphone jack module can in most cases be changed without removing the receiver unit from the cardio machine 1 To remove the worn jack locate the two Philips screws on the front bottom of the unit They will be covered by a felt insert on either side of the headphone power logo 2 Remove these two s...

Page 5: ...the front of the unit 4 Connect the other end of one of the C SAFE cables from step 2 to the master receiver and the second C SAFE cable to the slave receiver 5 On the master receiver locate the small button in the headphone jack compartment 6 Press this button once ARG Audio recommends using a paperclip for this 7 At this point the backlight on both the master and slave receiver will turn on This...

Page 6: ...ow ARG 900AR 900 MHz Analog Receiver Purchased after 1 1 2014 2 Years Warranty only applies to the original buyer Warranty is void if products have been damaged due to accident misuse abuse improper service mechanical or electrical non ARG Inc authorized modification ARG Inc is not liable without limitation to any person or entity for any direct incidental consequential damages or medical expenses...

Reviews: