background image

RE. ENR.110 - Rév B – le 15/03/2014 

 

  page : 19 

Notes 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for CH1-1250B

Page 1: ... model CH2 125B model CO 1000B model CH1 1250B model CH2 1250B model CH2 2000B model CH2 4000B model CH2 7000B Zone Industrielle Sud Rue Marc Séguin 41100 Vendôme Tel 33 0 2 54 80 79 30 Fax 33 0 2 54 80 79 31 E mail aremeca wanadoo fr site www aremeca instrumentation com Operating Instructions English Your Model Serial number Made the to contact Sales Manager d regal aremeca fr ...

Page 2: ...RE ENR 110 Rév B le 15 03 2014 page 2 ...

Page 3: ...el CH1 1250B 12 c Pressure generator models CH2 1250B and CH2 2000B and CH2 4000B and CH2 7000B and CO 800B and CO 1000B 14 5 Cleaning Maintenance 15 a Cleaning 15 b Maintenance 15 c Inspection 16 d Connectors 16 Threads M10x100 G1 8 1 8 BSP TR 1 8 NPT 16 Threads M12x150 M16x150 M18x150 M20x150 G1 4 G3 8 G1 2 1 4 BSP TR 3 8 BSP TR 1 2 BSP TR 1 4 NPT 3 8 NPT 1 2 NPT 16 6 Annexes 17 Options 17 Read ...

Page 4: ...RE ENR 110 Rév B le 15 03 2014 page 4 ...

Page 5: ...r AREMECA reserves the right to alter the content or form of this manual at any time and without notice And to make technical amendments to change the product Responsibility AREMECA is not liable for any damage caused by not in accordance with intended usage non compliance with instructions for use use of the instrument by unqualified untrained operator a transformation modification of the device ...

Page 6: ... use as described in this document In this case of misuse or mishandling outside the technical specifications contained in this manual The instrument must be immediately isolated identified as inoperative and must be checked by our service department Precautions storage and transport It s necessary to take care of the unit during storage or transportation It must be protected from moisture shock e...

Page 7: ...d an installations commissioning of the instrument performance Personal protective equipment PPE The personal protective equipment must be defined in the security register of the user company and made available to the operator These devices are used to protect the operator from potential risks that impede their safety and health at work Protecting fluid Wear eye protection protects the eyes agains...

Page 8: ... environment You will get better performance if the temperature and humidity of the room are stable the workstation is clean and dry protected from drafts noise vibration and without passing Component Identification 1 capstan 2 axis of rotation 3 clamping knob 4 connector 5 valves A A and or B 6 sidesteps 7 filler cap Installation Assembly P 2000 bar Install pressure generator on a established sta...

Page 9: ... correct fluid Use the supplied oil Don t use other liquids Our devices are mounted and designed to a standard use They function with the fluid provided Some fluids such skydrol castor oil etc are corrosive and can damage the o ring of your device On request we can deliver a device designed for these fluids 4 Turn the capstan completely in the opposite direction of clockwise until it reaches the s...

Page 10: ...he operational statues of the pressure generator Noted During calibration of instruments with a large volume the amount of fluid in the pressure generator may not be sufficient to achieve the desired pressure in this case the instrument must be filled as much as possible before being connected to the generator to reduce the useful volume of dluid As an alternative we provide you with a hand pump R...

Page 11: ...e instrument to be tested b Check the valve A is open c Check the capstan 1 the pressure generator is in end position stop d Close the valve A turn the capstan 1 in the direction of clockwise you can build up pressure up to 120 bar Maximum operating pressure 150 bar e Make the measurement point Reduce pressure f After the readings measures turn the capstan 1 in the opposite direction clockwise unt...

Page 12: ...instrument to be tested G1 2 1200bar M16x150 1200 bar b Check the valves A A are open the valve A is not marked on the crankcase c Check the capstan 1 pressure generator is in the end position d Close the valve A e Turn the capstan 1 in the direction of clockwise f If the resulting pressure is not sufficient g Close the valve A h Open the valve A i Turn the capstan 1 in the opposite direction of c...

Page 13: ... 15 03 2014 page 13 Reduce pressure o After the readings measures turn the capstan 1 in the opposite direction clockwise until the end position of the stop and slowly open the valve A p The instruments can be disassembled ...

Page 14: ...x150 1200 bar b Check the valves A and B are open c Check the capstan 1 pressure generator is in the end position d Close the valve A turn the capstan 1 in the direction of clockwise you can build up pressure up to 120 bar Maximum operating pressure 150 bar Make readings of measurements points in this measuring To generate higher pressures close the valve B and open the valve A turn the capstan 1 ...

Page 15: ...termediate valve is possible by interposing it between the bench and the device We repeat the cycle as many times as necessary For these applications a specific kit can be supplied It can also fill in advance before mounting the pressure generator b Maintenance Piezometric set It s designed for extremely narrow limits of accuracy It s forbidden to disassemble it Valves Generator and dead weight ar...

Page 16: ...ient the ring according to the type of connector correctly Thread M10x100 G1 8 1 8 BSP TR 1 8 NPT For these connectors guide ring mark 000 visible The connector must be tightened by hand Thread M12x150 M16x150 M18x150 M20x150 G1 4 G3 8 G1 2 1 4 BSP TR 3 8 BSP TR 1 2 BSP TR 1 4 NPT 3 8 NPT 1 2 NPT For these connectors guide ring mark visible The connector must be tightened by hand Available as an o...

Page 17: ...x150 OP0171 Suitcase with 4 connectors gas cylindrical G1 8 G1 4 G3 8 G1 2 OP0172 Suitcase with 4 connectors NPT 1 8NPT 1 4NPT 3 8NPT 1 2NPT OP0173 Suitcase with 4 connectors BSPTR 1 8BSPTR 1 4BSPTR 3 8BSPTR 1 2BSPTR OP0037 Suitcase with 17 connectors all connectors Kit cleaning OP0025 Cleaning kit for tank OP0062 Cleaning bench for manometers OP0023 Separator Transport OP0002 Suitcase for dead we...

Page 18: ...RE ENR 110 Rév B le 15 03 2014 page 18 Notes ...

Page 19: ...RE ENR 110 Rév B le 15 03 2014 page 19 Notes ...

Page 20: ...RE ENR 110 Rév B le 15 03 2014 page 20 ...

Reviews: