Arecont Vision HSG2 Installation Manual 

12 |  P a g e

 

 

HSG2 Pole Mount Adapter (MD-PMA) Installation Instructions

 

 
Inside the box: 

A.  Pole Mount Adapter 
B.  2x Compression Fittings 
C.  2x Small Steel Straps 
D.  2x Large Steel Straps 
E.  Pack of four (4) machine screws  

Not included but needed: 

 

#2 Phillips head screwdriver 

 MegaDome

® 

 Wall Mount, MD-WMT2 

 

Image 14        

1. 

Remove pole mount adapter, compression 
fittings, steel straps and hardware from the 
box.  

2. 

Install compression fittings to pole mount 
adapter as shown in 

Image 15

.  

3.      Run the Ethernet cable and outside power 

cable (if necessary) through the compression 
fittings.

 

 

4. 

Attach the wall mount to pole mount adapter 
as shown in 

Image 16

5.      Use the supplied two large or small steel 

straps to attach the pole mount adapter to the 
pole and tighten the compression screws as 
shown in 

Image 16

6.      Attach HSG2 housing to wall mount adapter. 

Please reference “

Mounting the Camera,

” if 

needed. 

7.      Tighten the compression fittings to seal the 

wiring holes. 

 

Image 15

 

 

Image 16 

A

 

B

 

C

D

E

Steel

 

Strap

 

Summary of Contents for HGS2

Page 1: ...Arecont Vision HSG2 Installation Manual 0 P a g e...

Page 2: ...the Camera 1 Remove HSG2 housing and hardware from the box 2 Open the HSG2 housing by using the provided wrench to loosen the two screws shown in Image 2 NOTE Do not remove screws from the housing Ima...

Page 3: ...at sink shown in Image 5 Image 5 6 Remove the silicone cap from the housing cut the side part if necessary Image 6 to run the RJ45 cable external power and digital in out cables through the silicone c...

Page 4: ...ra to the HSG2 PoE data output Image 9 10 Switch HSG2 power source to PoE power shown in Image 9 NOTE If the camera is powered via PoE please skip step 11 12 11 If the HSG2 housing is powered by an ou...

Page 5: ...ed 2 Phillips head screwdriver Image 10 1 Remove wall mount and hardware from the box Image 11 2 Run the Ethernet cable and outside power cable if necessary through the wall mount 3 Install the HSG2 h...

Page 6: ...river HSG2 WMT HSG2 Wall Mount NPT Conduit if necessary Image 12 1 Remove the junction box and hardware from the box Image 13 2 Remove the conduit plug by first removing the socket set screw by using...

Page 7: ...d hardware from the box 2 Install compression fittings to pole mount adapter as shown in Image 15 3 Run the Ethernet cable and outside power cable if necessary through the compression fittings 4 Attac...

Page 8: ...ter compression fitting and hardware from the box 2 Install compression fittings to corner mount adapter as shown in Image 18 3 Run the Ethernet cable and outside power cable if necessary through the...

Page 9: ...Arecont Vision HSG2 Installation Manual 8 P a g e...

Reviews: