WEB BROWSER-BASED CONFIGURATION
126
6.5.5 Activate Incomplete Raid Set
If one of the disk drives is removed in power off state, the RAID
set state will change to “Incomplete State”. If the user wants to
continue to operate the controller without power-off the 6Gb/s
SAS RAID controller, the user can use the “Activate Incomplete
Raid Set” option to active the RAID set. After the user completes
this function, the Raid State will change to “Degraded Mode” and
start to work.
To activate the incomplete the RAID set, click on the “Activate
Raid Set” link. A “Select The RAID SET To Activate” screen is
displayed showing all RAID sets existing on the current controller.
Click the RAID set number to activate in the select column.
Click on the “Submit” button on the screen to activate the RAID
set that had a disk removed (or failed) in the power off state.
The 6Gb/s SAS RAID controller will continue to work in degraded
mode.
6.5.4 Offline Raid Set
This function is for customer being able to unmount and remount
a multi-disk volume. All Hdds of the selected RAID set will be put
into offline state, spun down and fault LED in fast blinking mode.
User can remove those Hdds and insert new Hdds on those empty
slots without needing power down the controller
to perform the
online array roaming.