VMX Series Manual
page 55
rev 1.06
ON/OFF/Switch/Hold Button
The ON/OFF/Switch/Hold buttons allows the user to perform read/write operations to
single bit types. Immediately after the button is created the following configuration
screen will appear.
Data
a.
Action: Select action type for the button
a.
0 – Set ON: Pressing the button will set the bit value on. Because
b.
1 – Set OFF: Pressing the button will set the bit value off.
c.
2 – Set Switch: Pressing the button will set the bit opposite of the
current state.
d.
3 – Set Hold: Pressing the button will set the bit value on. Releasing
the button will set the bit value off.
Note: Because Arcus bit commands do not actually accept a 0 or 1 value
the ON/OFF/Switch and Hold commands all produce to same behavior.
Therefore it is recommended to always use the [0 - Set On] option.
b.
Read Address: Input the read address data. The data type must be of bit type.
Note: Arcus bit commands do not support the read feature. However this
this field must not be blank. Therefore it is recommended to always set
address to be the same as the write address.
c.
Write Address: Input the write address data. The data type must be of bit
type.