VMX Series Manual
page 24
rev 1.06
2)
Set Value Button Settings: Immediately after the set value button is created the
following configuration screen will appear.
Data
i.
Action: Select action type for the button
a.
0 – Input: Default setting for a set value button. This option requires
the user to input a value via a key pad
b.
1 – Var/Const: This option will write the parameter or constant in the
[Rule] field.
c.
2 – Inc/Dec: This option will increment or decrement the parameter by
the value inputted in the [Rule] field. Sample values for the [Rule]
field are: “+1”, “-1”
j.
Format: Set to 32-bit signed to match the data type of the [V29] parameter.
k.
Write Address: Input the write address data. Since we are reading from an
Arcus controller we type “1:V29”. This signifies the [V29] parameter of
device 01. To have the variable automatically created click on the [Exp] icon
on the right.
1