Enter custom settings
Press “ENTER” to access menu
Press “ENTER” to access
custom settings
Press “ENTER” to type password
The password is “0000” -
Press “ENTER” to enter the
highlighted number and press
“ENTER” to continue
Press “Esc” to exit menu/go back. The display will return to the main screen
after 1 minute of inactivity. When you have entered the custom menu
successfully, you will have the following options:
Setpoint
The setpoint defines the target temperature inside the appliance.
When changing the setpoint please check the “High/low temperature alarm”
and make sure they are in accordance with the new temperature setting. The
alarm temperatures are not automatically updated. Please refer to the “High/
low temperature alarm” sections of the manual for information on these set-
tings.
Press “ENTER” to access main menu
Press “ENTER” to access
‘Custom settings’
Press “ENTER” to enter the
password
The password is “0000” -
Press “ENTER” to enter the
highlighted number and press
“ENTER” continue
Press “ENTER” to access ‘Setpoints’
Press to increase or
decrease the value of the setpoint.
Press to highlight “Save” and
press “ENTER” to save the new
setpoint
Attention!
The Setpoint can only be set between the minimum and maximum value.
21
Controller operation/settings
Custom settings
Advanced Settings
Advanced service settings
Status
Change/Reset password
20
How to change the setpoint
Alarm settings
-
Temp. Alarm delay
- The temperatrure Alarm delay defines the number of
minutes between the temperature in the appliance crossing the alarm limit
and the alarm being activated. After changing the “Temp. Alarm delay” setting,
the appliance has to be restarted for the changes to take effect.
Press
“Esc”
until the display returns to the main screen. To activate the
settings, press the “On/Off” button to turn off the appliance, and then wait 10
seconds, press it again to turn on the appliance. The new settings are now in
effect.
- Door open alarm -
The appliance is equipped with a door contact to register
whether the door is open or closed. If the door is not closed correctly or held
open for period of time, the visual and audible “Door open alarm” will be
activated. This is to make sure the door is properly closed and the
integrity of the items placed in the appliance is maintained. The alarm will
stop when the door is properly closed and the alarm has been
accepted in the display.
Please note that the alarm may be activated when moving products in or out
of the appliance or in other instances, where the door is held open for
extended periods of time.
Main menu
Summary of Contents for ULUF
Page 27: ...5080038 11 GB...