ORIGINAL OPERATING
INSTRUCTIONS
ULUF models
Ultra low temperature freezers -90°C
Ultra low temperature freezers -86°C
Low temperature freezers -40°C
Page 1: ...ORIGINAL OPERATING INSTRUCTIONS ULUF models Ultra low temperature freezers 90 C Ultra low temperature freezers 86 C Low temperature freezers 40 C...
Page 2: ...her information about the appliance Symbols Abbreviations Safety Intended use Personal safety Handling Transportation Moving the appliance Packaging Unpacking Inactivity for extended period Disposal I...
Page 3: ...the advantages of your appliance To meet the high quality demands required by the medical and pharmaceutical industry at least 10 of all appliances leaving Arctiko are carefully checked and tested to...
Page 4: ...te the appliance and make sure it is completely dry Disconnect the power cord Leave the door slightly open in order to prevent rot and mold Disposal In the event of disposal of the appliance observe r...
Page 5: ...ut the refrigerant Location Place the appliance in a location that satisfies the following conditions in or der to achieve optimal operating results Firm and levelled floor Placing the appliance on a...
Page 6: ...on must always be secured with a minimum 10 A fuse If more than one appliance needs to be installed each appliance must be connected to an individual fuse group When installing the appliance make sure...
Page 7: ...w and low temperature freezing with high performance and stability Standard features is filter less construction for less maintenance low noise level low energy consumption low heat dissipation and ex...
Page 8: ...ion Never insert probes through the door as this will danger the door gasket increase the ice build up and affect the temperature inside the appliance Display G214 The control panel is a multifunction...
Page 9: ...lay is mounted in the top panel 17 Push the button in order to access a temperature graph Push the buttons to navigate the data history for up to 10 days Push the Esc button in order to exit the menu...
Page 10: ...as a backup guaranteeing that your stored products will be kept at the set temperature An Arctiko appliance which offers dual cooling system can be identified by the denomination of D in the end of t...
Page 11: ...set between the minimum and maximum value 21 Controller operation settings Custom settings Advanced Settings Advanced service settings Status Change Reset password 20 How to change the setpoint Alarm...
Page 12: ...imit for a period longer than the Alarm delay the low temperature alarm is activated If products with a lower temperature than the low temperature alarm setting is placed against or close to the tempe...
Page 13: ...r will not be reactivated by accepting the alarm Recommended actions If it is a non recurring alarm the compressor can be reactivated by restarting the appliance switching the appliance off and on aga...
Page 14: ...27 Select language The default language of the controller is English The language can be changed in the Select language menu The available languages are English German Russian French Spanish Swedish...
Page 15: ...optional extra probes Probe 2 and Probe 3 for temperature monitoring The chamber probe is measuring the air temperature inside the appliance to control the operation of the cooling system when the co...
Page 16: ...fect the performance of the appliance negatively or cause damage to the appliance The technical data can be found on Arc tiko s website or by contacting the seller of the appliance 31 Service The serv...
Page 17: ...ess Hysteresis Press ENTER to access Temp range limits ATTENTION Do not change the hysteresis setting without contacting a service representative Use to choose probe Press ENTER to access Use to chang...
Page 18: ...ory setting 0000 In order to reset the password you need to require a reset password from your Arctiko distributor Contact your distributor for the code needed Press ENTER to access menu Press until C...
Page 19: ...or similar software This function also makes it possible for a service technician to analyze the data for troubleshooting in case of malfunctions for quick and accurate support Insert USB drive in th...
Page 20: ...eadout has been preformed each readout will create a set of files with the number increased by one The data00 txt file contains the most recent download The param00 txt file contains the parameter set...
Page 21: ...d Compressor alarm Marked with H if triggered Manual defrost Marked with H if cycle is running Auto defrost Marked with H if cycle is running Measurements tmp1 Temperature measured by 1st probe tmp2 T...
Page 22: ...rost Freezer 0 Manual defrost Freezer OK Hysteresis Freezer 2 0 Temp range limits Freezer Max 20 0 Freezer Min 40 0 42 Default settings ULUF 15 65 125 Description Arctiko default settings Customer set...
Page 23: ...0 Manual defrost Freezer OK Hysteresis Freezer 2 0 Temp range limits Freezer Max 40 0 Freezer Min 85 0 44 Default settings ULUF 490 490 2M 590 590 2M 890 890 2M Description Arctiko default settings Cu...
Page 24: ...mends a thorough examination twice a year and cleaning at least once a month General maintenance Perform following at least twice a year Lubricate hinges and gaskets Wipe off all excess lubricant Make...
Page 25: ...ter can damage the insulation materials and electrical components Dust off the inside of the compressor compartment using only a dry brush or a vacuum cleaner Parts of the refrigeration system of this...
Page 26: ...m the sunlight or heat source Frequent door openings may cause the temperature to rise Check if there has been frequent door openings Leave the door closed until the temperature in the appliance is st...
Page 27: ...5080038 11 GB...