R290 refrigerant is used for this equipment.
Caution!
Consult reprair manual/ower
’
s guide before attempting to install or service this product. All
safety precautions must be followed. Dispose of properly in accordance with federal or
local regulations. Risk of fire or explosion due to puncture of refrigerant tubing. Follow
handling instructions carefully.
Dirty condenser coil.
Evaporator coil iced over.
necessary.
Clean the condenser coil.
Unplug unit and allow coil to defrost. Make
sure thermostat is not set too cold. Ensure
that door gasket(s) are sealing properly.
Cabinet
temperature
is too warm.
Thermostat set too warm.
Blocking are flow.
Excessive amount of warm product
placed in cabinet.
Fuse blown or circuit breaker tripped.
Dirty condenser coil.
Prolonged door opening or door ajar.
Evaporator coil iced over.
Set thermostat to lower temperature.
Re-arrange product to allow for
Proper air flow. Make sure there is at least
four inches of clearance from evaporator.
Allow adequate time for product to cool
down.
Replace fuse or reset circuit
breaker.
Clean the condenser coil.
Ensure doors are closed when
not in use. Avoid opening doors
for long periods of time.
(see above)
Cabinet is
noisy.
Loose part(s).
Tubing vibration.
Locate and tighten loose part(s).
Ensure tubing is free from contact with
other tubing or components.