19
4.3.11 Output Terminals
Select output cable size based on Table 4 (following page).
Duty cycle(%)
Current (A)
Length (Ft)
Cable Size (AWG)
30
180
1 - 50
8
60
300
1 – 150
1/0
60
300
150 - 200
2/0
TABLE 4
4.3.12 Voltage Changeover
The Voltage Changeover opening is located on the rear panel, to the right of the
input power cable. Voltage changeover is easily facilitated by inserting a flat blade
screwdriver into the opening and rotating a quarter turn. In the Low Vorlage (240V)
setting, the blade is horizontal and for the Hight Voltage (480V), setting the blade is
vertical.
See 4.5 Dual Voltage Changeover for additional information
FIGURE 4
RANGE SWITCH
4.3.3
POWER ON
INDICATOR
4.3.8
PROCESS CONTROL
STICK
SHORT ARC MIG
SPRAY MIG
4.3.7
WELD POWER
4.3.4
ARC
FORCE/PUDDLE
CONTROL
4.3.5
CIRCUIT BREAKER
(POWER ON/OFF)
4.3.1
OUTPUT TERMINALS
4.3.11
REMOTE CONTROL
CONNECTOR
4.3.9
INPUT POWER
CORD
12 FT (3.65m) LONG
4.3.10
THERMOSTAT
CONTROLLED
VENTILATION
4.3.2
VOLTAGE
CHANGE OVER
4.3.12
I
MIGWELD
300SM