61
Appendix C
Default Factory Command Codes
These are the “Factory default” codes when the RC210 is unlocked:
15281
Port 1 Unlock
25281
Port 2 Unlock
35281
Port 3 Unlock
1100
Port 1 Receiver Disable
2100
Port 2 Receiver Disable
3100
Port 3 Receiver Disable
1101
Port 1 Receiver Enable
2101
Port 2 Receiver Enable
3101
Port 3 Receiver Enable
1110
Port 1 Transmitter Disable
2110
Port 2 Transmitter Disable
3110
Port 3 Transmitter Disable
1111
Port 1 Transmitter Enable
2111
Port 2 Transmitter Enable
3111
Port 3 Transmitter Enable
1120
Port 1 Carrier Only Access
2120
Port 2 Carrier Only Access
3120
Port 3 Carrier Only Access
1121
Port 1 CTCSS/Carrier Access
2121
Port 2 CTCSS/Carrier Access
3121
Port 3 CTCSS/Carrier Access
1130
Port 1 Covertone Off
2130
Port 2 Covertone Off
3130
Port 3 Covertone Off
1131
Port 1 Covertone On
2131
Port 2 Covertone On
3131
Port 3 Covertone On
1134x
Port 1 CT Select
2134x
Port 2 CT Select
3134x
Port 3 CT Select
1140
Port 1 Repeat OFF
2140
Port 2 Repeat OFF
3140
Port 3 Repeat OFF
1141
Port 1 Repeat ON
2141
Port 2 Repeat ON
3141
Port 3 Repeat ON
1150
Port 1 Kerchunk Off
2150
Port 2 Kerchunk Off
3150
Port 3 Kerchunk Off
1151
Port 1 Kerchunk On
2151
Port 2 Kerchunk On
3151
Port 3 Kerchunk On
1160
Port 1 DTMF Disable
2160
Port 2 DTMF Disable
3160
Port 3 DTMF Disable
1161
Port 1 DTMF Enable
2161
Port 2 DTMF Enable
3161
Port 3 DTMF Enable
1170
Port 1 no PL for DTMF
2170
Port 2 no PL for DTMF
3170
Port 3 no PL for DTMF
1171
Port 1 PL for DTMF
2171
Port 2 PL for DTMF
3171
Port 3 PL for DTMF
1180
Port 1 Speech ID Over Off
2180
Port 2 Speech ID Over Off
3180
Port 3 Speech ID Over Off
1181
Port 1 Speech ID Over On
2181
Port 2 Speech ID Over On
3181
Port 3 Speech ID Over On
1190
Port 1 Monitor Mute
2190
Port 2 Monitor Mute
3190
Port 3 Monitor Mute
1191
Port 1 Monitor Mix
2191
Port 2 Monitor Mix
3191
Port 3 Monitor Mix
1200
Port 1 Speech Over Off
2200
Port 2 Speech Over Off
3200
Port 3 Speech Over Off
1201
Port 1 Speech Over On
2201
Port 2 Speech Over On
2201
Port 3 Speech Over On
1210
Port 1 DTMF Mute Off
2210
Port 2 DTMF Mute Off
3210
Port 3 DTMF Mute Off
1211
Port 1 DTMF Mute On
2211
Port 2 DTMF Mute On
3211
Port 3 DTMF Mute On
1220
Port 1 DTMF on COS
2220
Port 2 DTMF on COS
3220
Port 3 DTMF on COS
1221
Port 1 DTMF on CTCSS
2221
Port 2 DTMF on CTCSS
3221
Port 3 DTMF on CTCSS
1300
Monitor Port 2 From Port 1 Off
1301
Monitor Port 2 From Port 1 On
1310
Monitor Port 3 From Port 1 Off
1311
Monitor Port 3 From Port 1 On
2300
Monitor Port 1 From Port 2 Off
2301
Monitor Port 1 From Port 2 On
2310
Monitor Port 3 From Port 2 Off
2311
Monitor Port 3 From Port 2 On
3300
Monitor Port 1 From Port 3 Off
3301
Monitor Port 1 From Port 3 On
3310
Monitor Port 2 From Port 3 Off
3311
Monitor Port 2 From Port 3 On
1400x
Read Meter
1500x
Reset Meter hi/low value
1600x
Meter Alarm ON/OFF
2700
Allow DTMF into Phone Line
2701
Mute DTMF into Phone Line
2800
Macro Subset OFF
2801
Macro Subset ON
1700
Say Time
1701
Say Date
18yx
UF1(y) to UF7(y) x=ON/OFF
180
UF Extended
A71
Remote Base Frequency
A72
Remote Base CTCSS
A73
Remote Base Mode
A74
Doug Hall User Function
A75x
Memory Select
A76x
Doug Hall Memory Select
A77xy
V7a/G707 Memory Recall
A79x
RB Power Select
1910
Alarm 1 Off
1911
Alarm 1 On
2910
Alarm 2 Off
2911
Alarm 2 On
3910
Alarm 3 Off
3911
Alarm 3 On
4910
Alarm 4 Off
4911
Alarm 4 On
5910
Alarm 5 Off
5911
Alarm 5 On
1913
Alarm 1 Interrogate
2913
Alarm 2 Interrogate
3913
Alarm 3 Interrogate
4913
Alarm 4 Interrogate
5913
Alarm 5 Interrogate
A11
Link Port 1 & Port 2
A21
Link Port 1 & Port 3
A31
Link Port 2 & Port 3
A41
Link All Ports
A10
UnLink Port 1 & Port 2
A20
UnLink Port 1 & Port 3
A30
UnLink Port 2 & Port 3
A40
Unlink All Ports
1960
Aux Audio 1 Off
1961
Aux Audio 1 On
2960
Aux Audio 2 Off
2961
Aux Audio 2 On
3960
Aux Audio 3 Off
3961
Aux Audio 3 On
AA1
Play CW ID 1
AA2
Play CWID 2
AA3
Play Voice ID 1
AA4
Play Voice ID 2
AA5
Play Voice ID 3
10901 to 109090
Recall Macro 1 to 90
Summary of Contents for RC210
Page 2: ...2 this page intentionally left blank ...
Page 66: ......