![Arcom Digital Quiver XT User Manual Download Page 79](http://html.mh-extra.com/html/arcom-digital/quiver-xt/quiver-xt_user-manual_2964792079.webp)
79
TDR Mode
Return Port TX chirp probe signal: 5MHz – 45MHz
BW = 4.0 MHz
RF Output levels: -10dBmV to +10 dBmV (± 3.5dBmV)
Max cable length: 1865ft
Cable distance accuracy: 2 feet
Coaxial cable Settings: RG11, RG6, 440, 500, 540, 625, 650, 750, 875, 1000, 1125
CPD Passive radar mode
CPD echo signal bandwidth: 8-16MHz standard resolution, 6 - 42/100 MHz - high
resolution (zoom)
FWD input signal level: -10to +25dBmV
CPD Active radar mode
Forward Port Output: TX chirp probe signal: 150 - 250 MHz
RX CPD echo signal bandwidth: 5 to 100 MHz
RF output level: +30 dBmV to +50 dBmV (± 3.5dBmV)
Bandwidth of FFT spectrum analyzer: +/- 20 kHz
Leakage Detector
Tuner frequency step: 1 kHz
ResBW: 20 Hz
Sensitivity: -150dBm
RTN Sweep Generator
Sweep TX Output: +10 dBmV to +35 dBmV ±1.5 dB, 1 dB steps
Fixed Sweep: Up to 64 frequency steps from 5 MHz to 90 MHz in 100 KHz
increments. Default Profile #0, which cannot be deleted is 5 MHz to 90 MHz in 1.5
MHz steps.
Manual Sweep: 16 frequency steps from 5 MHz to 90 MHz / 100 KHz increments
Sweep Time: 5 mS to 10 mS.