If you receive this error message, first check the connection and then check the
Data Carrier, then switch the output signal on to try calibration again. Repeat this
process until you the forward signal ok message.
When the Headend Radar successfully receives the calibration signal the Quiver
receives the confirmation signal and displays the following successful node calibration
message:
In this case no further action is required.
The data is automatically validated in the
Hunter database.
However, if the Headend Radar scans the fiber
node but does not receive the node’s calibration
signal, the following error message below appears
on the screen:
Calibration Error Message
In this situation, first check the connection. If the connection is secure, increase the
output signal level in 5dBmV steps until the system shows calibration confirmation
screen. Remember to confirm each signal level change with <ENTER> button.