Y-LED Upgrade Kit Installation Guide
Fixture: FGL - Federal Globe Large Scale (FGL) - For SLG/PA3/PA5 Lens
A R C H I T E C T U R A L A R E A L I G H T I N G
93049778 REV. A
PAGE 2/5
www.aal.net
16555 East Gale Avenue
City of Industry, CA 91745
626.968.5666
FIG. 1-2
1.
REMOVE EXISTING REFLECTOR ASSEMBLY
TURN OFF ALL POWER TO
THE UNIT AND TAKE PROPER SAFETY
PRECAUTION. FAILURE TO DO SO MAY RESULT IN
SERIOUS PERSONAL INJURY.
1. REMOVE FINIAL BY TURNING IT COUNTER
CLOCKWISE. (FIG. 1-1)
2. REMOVE GASKET AND TOP LENS ASSEMBLY.
DO NOT DISCARD. (FIG. 1-1)
3. WITH A PHILLIPS HEAD SCREW DRIVER REACH
INSIDE THE REFLECTOR FROM THE TOP AND
LOOSEN THE THREE SCREWS. ROTATE THE
STACK REFLECTOR AND REMOVE FROM CAST
LID. (FIG. 1-2)
!
FIG. 1-1
FINIAL
GASKET
TOP LENS
ASSEMBLY
STACK
REFLECTOR
CASTING LID
BOTTOM
LENDS
SCR-8-32 x 3/8"
PHLPS PHMS S/S
3X