Y-LED Upgrade Kit Installation Guide
Fixture: FGS - Federal Globe Small Scale (FGS) For SAL Lens With CCO Optical System
A R C H I T E C T U R A L A R E A L I G H T I N G
93049779 REV. A
PAGE 5/5
TM
www.aal.net
16555 East Gale Avenue
City of Industry, CA 91745
626.968.5666
4. INSTALLING DRIVER ASSEMBLY
FIG. 4-1
FIG. 4-2
GLOBE
ASSEMBLY
LATCH
DRIVER
ASSEMBLY
QUICK-
DISCONNECT
CAST
BALLAST
HOUSING
1. TILT GLOBE ASSEMBLY TO THE SIDE BY
PULLING LATCH BACKWARD. (FIG. 4-1)
2. INSTALL DRIVER ASSY. (FIG. 4-1)
3. MAKE WIRE CONNECTIONS BY
CONNECTING QUICK DISCONNECT FROM
DRIVER ASSY TO SOCKET ASSY AND
LIFESHIELD QUICK DISCONNECT. (FIG. 4-2)
4. CLOSE FIXTURE, ENSURE LATCH SNAPS
BACK TO ITS ORIGINAL POSITION.
(FIG. 4-3)
5. MAKE WIRE CONNECTIONS FROM
INCOMING TO DRIVER ASSY: WHITE TO
WHITE, BLACK TO BLACK AND GREEN TO
GREEN. (FIG. 4-3)
6. INSTALLATION COMPLETE.
INCOMING
BLACK
WHITE
GREEN
BLACK
WHITE
GREEN
GRAY
PURPLE
FIG. 4-3
LATCH
LIFESHIELD
QUICK DISCONNECT