Regularly:
•
Frequent cleaning of the ceramic glass is required. Archgard recommends using a good
quality “gas fireplace” glass cleaner that is available at any hearth retail location. DO NOT
CLEAN WHILE HOT.
•
Clean and remove any lint accumulations or debris from the grills and in any combustion
and convection air passage ways.
•
Keep the appliance area free from combustible materials, such as paper, wood, clothing,
gasoline and flammable solids, liquids and vapors.
•
Visually check the height and color of the burner and pilot flames.
Every 2 to 3 months:
•
Remove the glass door and clean the inside of the glass with a good quality “gas
fireplace” glass cleaner. DO NOT CLEAN WHILE HOT.
•
Carefully remove the logs and gently brush off any loose carbon deposits. This job is best
done outside the house, wearing a dust mask.The logs are very fragile, take care not to
break them.
Do not wash logs with any liquid.
While the logs are removed, check that
all burner openings are not obstructed and it is recommended you use a vacuum cleaner
to clean off any dust or lint.
•
After cleaning, the logs must be replaced as per the instructions in this manual.
Once a year, have a qualified service technician:
•
Completely inspect the appliance and the venting system, if the vent pipe or seal is found
to be defective, replace and or reseal (follow the instructions found in the installation
section)
•
Clean and remove any lint accumulations or debris in the firebox, on the burners, on the
pilot, at the primary air opening, on the convection air blower and in any combustion and
convection air passageways.
•
Check the safety system of the gas valve and the appliance.
MAINTENANCE
CAUTION:
Do not conduct maintenance on the appliance while it is operating or while it is still hot.
The exterior painted surfaces, glass and gold trims may be cleaned with a soft, non-abrasive
cloth and water or a suitable, mild, non-abrasive cleaner.
WARNING : All parts removed or disturbed, including guards and grills, must be
properly replaced after maintenance. Service and repair must be
conducted by a qualified service person. If these instructions are not
followed, a fire or explosion may result, causing property damage
,
personal injury or loss of life.
CLEANING THE APPLIANCE